After July 1, 2012, the following shall be required for water closets and toilets: (1) Dual flush. Dual flush water closets and toilets must meet the following standards: a. The average flush volume of two reduced flushes and one full flush may not exceed 1.28 gallons; b. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as applicable: 1. American Society of Mechanical Engineers Standard A112.19.2-2008; 2. American Society of Mechanical Engineers Standard A112.19.14-2006 Six-Liter Water Closets Equipped with a Dual Flushing Device"; and 3. Is listed to the WaterSense Tank-Type High Efficiency Toilet Specification; or (2) Single flush. Single flush water closets, including gravity, pressure assisted, and electro-hydraulic tank types, must meet the following standards: a. The average flush volume may not exceed 1.28 gallons; b. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and c. The toilet must be listed to the WaterSense Tank-Type High Efficiency Toilet Specification.