Marion County · Code of Ordinances
Chapter 26 - ENVIRONMENT / Article II - GROUNDWATER RECHARGE AREA PROTECTION
Sec. 26-71. Section M of manual for on-site sewage management systems.
About this text
- As published by Municode, current through 2022-03-08
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The text set forth in this section is from the state department of human resources manual for on-site sewage management systems, section M, pages M-1 and M-2, and is included here for convenience only. In the event of any conflict between the following text and the referenced manual, the referenced manual shall govern:
(1) Lot sizing. To provide for the orderly and safe development of property utilizing on-site sewage management systems, minimum lot sizes have been established. Larger lot sizes may be required to meet the requirements of this manual depending on the proposed development of the property. County boards of health and/or county zoning authorities may require larger minimum lot sizes; the larger minimum lot sizes will take precedence.
a. Single-family dwellings. Lot size requirements are for single-family dwellings, including, but not limited to, manufactured or mobile homes, stick built homes, modular homes, etc., and individual lots in subdivisions or mobile home lots located in areas other than commercial mobile home parks. Area requirements for multiple dwellings on a single recorded lot, where not prohibited by local zoning, must be provided in multiples of the following minimum lot sizes for each dwelling to be constructed on the recorded lot. See table MT-1 and subsections (1)a.1—6 of this section as follows:
Table MT-1 Minimum (Min.) Lot Sizes, Minimum Lot Widths and Maximum (Max.) Allowable Sewage Flow for the Type of Water Supply System
Minimum Lot Size Requirements Type of Water Supply System Nonpublic* (individual) Public Minimum lot size 43,560 square feet (one acre) 21,780 square feet (onehalf acre) Minimum lot width 150 feet 100 feet Maximum sewage flow 600 gallons/acre/day 1200 gallons/acre/day
5. There must be an unobstructed area on each lot for installation of an approved on-site sewage management system and an area equal in size for a conventional system or larger area, as appropriate, for an approved replacement system; this will include sufficient area for necessary site modifications for installation of both the initial system and a replacement system. All pertinent county zoning setbacks and other space requirements must be also be met.
6. The maximum daily sewage flow for each lot or parcel of land shall not exceed 600 gpd when served by nonpublic or individual water supply system or 1,200 gpd when served by public water supply system. When sewage flows exceed these qualities (600 or 1,200 gpd as indicated) for a given dwelling structure, the minimum lot size or parcel of land shall be increased proportionally. Example: Assume a public water supply exists (so 1,200 gpd maximum sewage flow allowed per minimum required land area of 21,780 square feet), and there is a proposed sewage flow of 5,000 gpd.
(i) To determine X = the square footage of the lot needed, use the following formula:
X = 5,000 gallons/acre/day 1,200 gallons/acre/day = 4.17 acres = 4.17 acres × 43560 ft2 /acre = 181,500-foot2 area of land needed (ii) Likewise, for a nonpublic (individual) water supply, to determine Y = the square footage of the lot needed for a proposed sewage flow of 5,000 gpd, use the following formula:
Y = 5000 gal/day 600 gal/acre/day = 8.33 acres = 8.33 acres × 43560 ft2 /acre = 363,000 ft2 area of land needed
b. Lot sizing requirements are as follows: for multifamily residential dwellings, and other non-single-family dwelling and commercial structures, and this also includes mobile homes located in commercial mobile home parks. Subsections (1)a.1—6 of this section also apply to table MT-2.
Table MT-2 Minimum (Min.) Lot Sizes, Minimum Lot Widths and Maximum (Max.) Allowable Sewage Flow for the Type of Water Supply System
Minimum Lot Size Requirements Type of Water Supply System Nonpublic* (individual) Public Minimum lot size 43,560 square feet (one acre) 21,780 square feet (onehalf acre) Minimum lot width 150 feet 100 feet Maximum sewage flow 600 gallons/acre/day 1,200 gallons/acre/day
d. Local governments at their option may exempt from the requirements any lot of record prior to the date of adoption of the rules of the Georgia Department of Natural Resources, Environmental Protection Division, ch. 391-3-16-.02, pertaining to criteria for protection of groundwater recharge areas.
History
(Ord. of 11-13-2001, appendix)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.