(a) On or after July 1, 1991, no construction may be initiated within the county for any residential building of any type which: (1) Employs a gravity tank-type, flushometer-valve, or flushometer-tank toilet that uses more than an average of 1.6 gallons of water per flush; provided, however, this subsection shall not be applicable to one-piece toilets until July 1, 1992; (2) Employs a shower head that allows a flow of more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure; (3) Employs a urinal that uses more than an average of 1.0 gallons of water per flush; (4) Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than 2.0 gallons of water per minute; or (5) Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than 2.5 gallons of water per minute. (b) On or after July 1, 1992, there shall be no construction of any commercial building initiated within the county for any commercial building of any type which does not meet the requirements of subsections (a)(1) through (5) of this section.