(a) Size of sewers. Sewers connecting component parts of on-site sewage management systems shall be of sufficient size to serve anticipated flow conditions.
(b) Sewers. All solid pipe and fittings used in an on-site sewage management system, beginning at the house, shall be NSF International schedule 40 PVC or equivalent and shall be a minimum of four inches in diameter. Sewers under driveways or similar areas of load or impact shall be of material capable of withstanding anticipated loads or installed so as to provide protection from crushing.
(c) Construction. Sewers, other than perforated pipe or drain tiles used in absorption fields, shall be laid with sealed, watertight, root-resistant joints. Such sewers shall be laid on a firm foundation, shall not be subject to settling, and shall be installed on a grade that will ensure a self-cleaning velocity. Where on-site sewage management systems are used, and where installation of building drains and building sewers is not covered by duly adopted local plumbing codes, or in the absence of a local plumbing code and/or plumbing inspections, the county board of health may verify the adequacy and acceptability of all or any portion of the building sewer or the building drain.
History
(Code 1991, § 14-84; Ord. No. 02-04, 7-23-2002)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.