--- title: Meriwether County Code of Ordinances, Sec. 36-23. Septic tanks collection: local-codes id: local-code:meriwether-county/code/36-23 cite_as: Meriwether County, Ga., Code of Ordinances § 36-23 canonical_url: https://georgiacommons.org/counties/meriwether/code/36-23 md_url: https://georgiacommons.org/counties/meriwether/code/36-23.md text_url: https://georgiacommons.org/counties/meriwether/code/36-23/text source_url: https://library.municode.com/ga/meriwether_county/codes/code_of_ordinances date: 2026-01-12 status: active jurisdiction: county:meriwether jurisdiction_name: Meriwether County county_fips: "13199" corpus_version: local-codes-meriwether-county-50e832dc19f4 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/meriwether/code/~part-ii/~chapter-36/~article-ii.md previous: https://georgiacommons.org/counties/meriwether/code/36-22.md next: https://georgiacommons.org/counties/meriwether/code/36-24.md index: https://georgiacommons.org/counties/meriwether.md branch: code edition: As published by Municode, current through 2026-01-12 edition_date_kind: current_through source_publisher: Municode version_id: local-code:meriwether-county/code/36-23@2026-01-12-285c9d64e1 --- # Meriwether County Code of Ordinances, Sec. 36-23. Septic tanks > As published by Municode, current through 2026-01-12 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 36 - WATER AND SEWERAGE / Article II - ON-SITE SEWAGE MANAGEMENT SYSTEMS (a) Minimum design and construction. Septic tanks shall provide a minimum of 24 hours of retention and shall be designed and constructed to equal or exceed minimum design and construction criteria established by the department as published in the current Manual for On-Site Sewage Management Systems. Any person seeking approval of septic tanks to be used in on-site sewage management systems, shall submit detailed plans and specifications for tank manufacture and other information as may be required by the department. Manufacturers and suppliers may be subject to periodic inspection, and approval by the county board of health or the department. Both the inlet and outlet tees shall be ASTM 3034 rated or equivalent. In addition, an approved filter shall be installed on the outlet end of the septic tank in compliance with the Manual for On-Site Sewage Management Systems. (b) Location. No septic tank shall be installed less than 50 feet from existing or proposed wells/ springs, sink holes, or suction water lines, and tanks shall be located downgrade from wells or springs if physically possible; less than 25 feet from lakes, ponds, streams, water courses, and other impoundments; less than ten feet from pressure water supply lines, or less than ten feet from a property line. No septic tank shall be installed less than 15 feet from a drainage ditch or embankment. Septic tanks shall be installed so as to provide ready access for necessary maintenance. Normally, the distance a septic tank should be located from a building foundation is at least ten feet but, lesser distances may be allowed by the county board of health. The county board of health, after site inspection, may require greater separation distances than cited herein due to unusual conditions of topography, or other site configuration; subsurface soil characteristics and/or groundwater interference. (c) Capacity. The liquid capacity of septic tanks for single-family dwellings shall be 1,000 gallons for one, two, three or four bedrooms, and 250 additional gallons for each bedroom over four. Septic tank capacity shall be increased by 50 percent where garbage grinders are to be used. Auxiliary systems serving single-family residences or other facilities shall be based on the maximum daily flow. (d) Compartmented tanks. Two compartment tanks shall be required. The first compartment shall be at least two-thirds the liquid capacity of the tank. (e) Tanks in series. The county board of health may approve the installation of tanks placed in series as equivalent to a single-compartmented septic tank. Tanks in series should be single-compartment tanks, with the first tank being at least 1,000 gallons and equal to two-thirds of the required liquid capacity. When tanks in series are used, they shall be connected with a sealed sewer line, and all sewage shall initially enter the first tank. (f) Foundation and backfill. Septic tanks shall be installed level on a foundation that will prevent settling; backfill shall be placed so that a stable fill results and undue strain on the tank is avoided. Earth backfill shall be free of voids, large stones, stumps, broken masonry, or other such materials. A minimum earth cover of six inches over the tank is recommended. With proper documentation the county board of health may approve less cover. All openings, risers and manholes shall be constructed so as to prevent the entrance of surface water. ## History (Code 1991, § 14-85; Ord. No. 02-04, 7-23-2002)