(a) The well site shall be graded, if necessary, to facilitate rapid drainage of surface water to a distance of not less than ten feet from the well in all directions or a diversion ditch or trench shall be constructed to effectively divert surface water from the well site. Pump platforms, pump room floors, and well slabs shall be protected from flooding by being located not less than two feet above the high water level of any nearby lake, pond or stream. The casing, liners, screens and any other manufactured material used in the construction of the well shall be of new material.

(b) It shall be the responsibility of the well contractor to ensure the protection of all bored wells from surface contamination by a four-inch-thick to six-inch-thick concrete well slab extending at least two feet in all directions from the casing and sloping away from the well. Bored or dug wells shall be cased and the annular space around the casing shall be sealed with cement grout to a depth of ten feet below the ground surface. Minimum thickness of the grout shall be six inches. The top of the casing must be capped with a concrete cap and/or well seal. Bored wells of less than 25 feet shall not be approved.

(c) All openings into a well, except a screened well vent, shall be sealed. Well vents are required for all drilled wells.When a vent is used, it shall be a riser pipe of a design where the screened opening terminates downward at least 12 inches above the surface or be of a design approved by the board of health. When pumping equipment is enclosed within a pump house or other enclosed shelter, a gravity drain from the structure shall be provided. Bored wells with the pump or terminals located below grade or within the well shall not be approved. This does not include submersible pumps designed and approved for this use.

History

The history line the source prints at the end of the section.

(Code 1991, § 14-130; Ord. No. 02-03, § 5:00, 7-10-2002)