Monroe County · Code of Ordinances
Part II - CODE OF ORDINANCES / Chapter 7 - FLOODPLAIN REGULATIONS / Article IV - PROVISIONS FOR FLOOD HAZARD REDUCTION
Sec. 7-83. Building standards for streams without established base flood elevations and/or floodway (Azones).
About this text
- As published by Municode, current through 2025-03-04
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Located within the areas of special flood hazard established in section 7-27, where streams exist but no base flood data have been provided
(A-zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply:
(1) When base flood elevation data or floodway data have not been provided in accorFLOODPLAIN REGULATIONS § 7-83 dance with section 7-27, then the planning and zoning Officer shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway
data available from a federal, state, or other source, in order to administer the provisions of this article. Only if data are not available from these sources, then the following subsections (2) and (3) shall apply.
(2) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or twenty (20) feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in more than a one (1) foot increase
in flood levels during the occurrence of the base flood discharge.
(3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three (3) feet above the highest adjacent grade at the
building site. (Note: Require the lowest floor to be elevated one (1) foot above the estimated base flood elevation in A-zone areas where a limited detail study has been completed). Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection 7-81(4).
All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three (3) feet above
the highest adjacent grade at the building site.
The planning and zoning officer shall certify the lowest floor elevation level and the record shall become a permanent part
of the permit file.
History
(Ord. of 5-6-08, Art. 4(§ C))
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.