--- title: Newton County Code of Ordinances, Sec. 10-87. Minimum requirements for light and ventilation collection: local-codes id: local-code:newton-county/code/10-87 cite_as: Newton County, Ga., Code of Ordinances § 10-87 canonical_url: https://georgiacommons.org/counties/newton/code/10-87 md_url: https://georgiacommons.org/counties/newton/code/10-87.md text_url: https://georgiacommons.org/counties/newton/code/10-87/text source_url: https://library.municode.com/ga/newton_county/codes/code_of_ordinances date: 2023-04-18 status: active jurisdiction: county:newton jurisdiction_name: Newton County county_fips: "13217" corpus_version: local-codes-newton-county-06c9c39fdfd1 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/newton/code/~part-ii/~chapter-10/~article-iii.md previous: https://georgiacommons.org/counties/newton/code/10-86.md next: https://georgiacommons.org/counties/newton/code/10-88.md index: https://georgiacommons.org/counties/newton.md branch: code edition: As published by Municode, current through 2023-04-18 edition_date_kind: current_through source_publisher: Municode version_id: local-code:newton-county/code/10-87@2023-04-18-21ee68d011 --- # Newton County Code of Ordinances, Sec. 10-87. Minimum requirements for light and ventilation > As published by Municode, current through 2023-04-18 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 10 - BUILDINGS AND BUILDING REGULATIONS / Article III - HOUSING CODE (a) Windows. Every habitable room is encouraged to have at least one window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be eight percent of the floor area of such room. Whenever walls or other portions of structures face a window of any such room and such light-obstruction structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, such an window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. (b) Ventilation. (1) Every habitable room shall be adequately ventilated. (2) Year round mechanically ventilating conditioned air systems may be substituted for windows, as required herein, in rooms other than rooms used for sleeping purposes. Window type air conditioning units are not included in this exception. (c) Bathroom. Every bathroom shall comply with the light and ventilation requirements for habitable rooms except that no window or skylight shall be required in adequately ventilated bathrooms equipped with an approved ventilating system. (d) Electric lights and outlets. Where there is electric service available to the building structure, every habitable room or space shall contain at least two separate and remote convenience outlets and bedrooms shall have, in addition, at least one wall switch controlled ceiling or wall type light fixture. In kitchens, three separate and remote convenience outlets shall be provided, and a wall or ceiling type light fixture controlled by a wall switch shall be required. Every hall, water closet compartment, bathroom, laundry room or furnace room shall contain at least one electric fixture. In addition to the electric light fixture in every bathroom and laundry room, there shall be provided at least one convenience outlet. Any new bathroom outlet shall have ground-fault circuit interrupter protection. Every such outlet shall be properly installed, shall be maintained in good and safe working condition, and shall be connected to the source of electric power in a safe manner. (e) Light in public halls and stairways. Every common hall and inside stairway in every building, other than one-family dwellings, shall be adequately lighted at all times with an illumination of at least one footcandle intensity at the floor in the darkest portion of the normally traveled stairs and passageways. ## History (Code 2001, § 36-111(2)(B); Ord. of 1-20-1987)