Skip to content
Georgia Commons
Menu

Oconee County · Code of Ordinances

Part - CODE OF ORDINANCES / Chapter 66 - UTILITIES / Article 11 - EROSION CONTROL AND STORMWATER MANAGEMENT / Division II - STORM DRAINAGE & STORMWATER MANAGEMENT / 1117 - Stormwater management in the non-urbanized area.

Sec. 1117.10. Catch basins and storm sewer structures.

About this text

  • As published by Municode, current through 2026-04-07
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

a. All catch basins and storm sewer structures shall be designed and constructed in compliance with Georgia D.O.T. Specifications and shall be Georgia D.O.T. Standard 1033D, 1034D, or 1019.

b. The use of a Standard 1019 shall be excluded from turnarounds and the low point of sag vertical curves draining more than 300 feet of gutter. Drainage calculations and design data are required for the use of a Standard 1019.

c. All drainage structures shall be constructed of reinforced precast concrete, 4-foot diameter or larger.

d. All 1033D and 1034D drainage structures shall require a reinforced precast "Round to Square" adapter for additional throat support.

e. All junction boxes shall include precast adapters and heavy duty traffic rated ring and covers. All junction boxes shall include approved steps, spaced 12 inches on center vertically, to allow safe access by maintenance personnel.

f. All storm sewer structures shall be reinforced precast or poured in place reinforced concrete. Masonry structures are not allowed unless authorized in writing by the Public Works Director.

g. No length of pipe shall exceed 200 feet without intermediate structures.

h. In certain instances where rolled or "hollywood" curb is utilized, the Public Works Director may require the use of 1033F and 1034F catch basins.

i. All structures shall have poured inverts to minimize accumulation of water and sediment in the structure.

j. All structure covers shall be cast to read "Oconee County Storm Sewer, Dump No Waste

- Drains to Stream".

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:oconee-county/code/1117.10@2026-04-07-a6a876cbd5

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.