Sec. 38-116. Sterilization.
About this text
- As published by Municode, current through 2026-04-07
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Cleaned instruments shall be packed individually in sterilized packs and sterilized in a medical grade autoclave. All sterilized packs shall contain either a sterilized indicator or internal temperature indicator.
(b) Prior to being placed in the autoclave all equipment shall be bagged, labeled, initialed, dated and sealed. Packages will no longer be considered sterile six months after the date of sterilization.
(c) Each autoclave bag must be used in accordance with the manufacturer's recommendations and may hold no more than one individual item (e.g., one tube or needle bar). A piercing set may be bagged together.
(d) The medical grade autoclave shall be used and maintained according to manufacturer's specifications. The medical grade autoclave shall be thoroughly cleaned and disinfected daily.
The autoclave manufacturer's instructions must be available at all times.
(e) After sterilization, the packaged instruments shall be stored in a clean dry cabinet or other tightly covered container reserved and labeled for storage of sterile instruments.
(f) If a sterilized package has been breached or allowed to get wet, the instrument(s) must be re-packaged and sterilized again before use.
(g) Spore indicators shall be used a minimum of at least once a month (unless more frequent monitoring is specified by the manufacturer) and the results must be kept on-site for a minimum of two years. An independent commercial testing laboratory contracted by the administrative body shall perform monthly biological spore testing of the autoclave. A provision shall be included in the contract between the administrative body with the commercial testing laboratory requiring the commercial testing facility to notify the health department of any failure of the autoclave to eradicate all living organisms, including spores.
(h) Upon notification of a positive microbiological monitoring report, the sterilizer shall be immediately checked for proper use and function, and the operator shall cease use of the sterilizer immediately upon receipt of the positive report. Three consecutive negative biological tests must be achieved before the establishment is reopened. The establishment shall have the option to obtain a properly functioning sterilizer with a negative biological report in order to remain open or if the facility has more than one autoclave in operation they may be given approval to remain open. The health department may consider the body tattoo/body piercing establishment's emergency plan should autoclave failure or malfunctions occur.