The maximum height of all buildings and structures in each zoning district, except as otherwise provided in this Section or as restricted in the Sign Regulations Article of this Development Code, shall be as shown on Table 4.1. a. If the building height exceeds 40 feet and/or is above the capability of normal firefighting equipment, local fire officials shall certify that such building, as proposed to be located, constructed and equipped and particularly the upper stories, has adequate sprinkler equipment or other built-in equipment to provide fire protection. b. Exemptions. (1) The height limitations shown on Table 4.1 do not apply to church spires, belfries, flag poles, monuments, cupolas, domes, ornamental towers, nor to observation towers not intended for human occupancy, water towers, transmission towers, radio or television towers or aerials,3 chimneys, smoke stacks, conveyors, derricks, elevator shafts or stairwell enclosures, nor to the necessary mechanical roof appurtenances nor to barns and silos when located on a farm. (2) The above exclusions from height limitations shall not apply in the vicinity of airports, private airstrips and heliports in accordance with FAA Regulations. c. Height limitations for fences and freestanding walls. The setback requirements of these Regulations shall not prohibit any necessary retaining wall nor prohibit any wall or fence except that in an R District: (1) No wall or fence shall exceed 8 feet in height within a side yard or rear yard; and (2) No wall or fence shall exceed 4 feet in a required front yard. Table 4.1: Dimensional Requirements by Zoning District MINIMUM LOT AREA1 2 AG AR-33 AR3 R-1 R-2 R-3 M-H4 OIP B-1 B-2 OBP I With Sewer 5 acres 3 acres 2 acres 1 acre 30,000 sf (single family) 30,000 sf (min. project size)6 30,000 sf 10,000 sf 10,000 sf 20,000 sf 40,000 sf 40,000 sf 30,000 sf (two family on one lot) 15,000 sf (two family on two lots/zero internal lot line) Without Sewer 5 acres 3 acres 2 acres 65,340 sf 51,000 sf (single family) N/A 51,000 sf 1 acre 1 acre 1 acre 1 acre 1 acre 51,000 sf (two family on one lot) 25,500 sf (two family on two lots/zero internal lot line) MINIMUM LOT AREA PER DU5 AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I With Sewer 5 acres 3 acres 2 acres 1 acre 30,000 sf (single family) 30,000 sf (single family) 30,000 sf — — — — — 15,000 sf (two-family on one lot) 15,000 sf (two-family) 15,000 sf (two family on two lots/zero internal lot line) 8,000 sf (multi-family) Without Sewer 5 acres 3 acres 2 acres 65,340 sf 51,000 sf (single family) — 51,000 sf — — — — — 25,5000 (two-family on one lot) 25,500 sf (two family on two lots/ zero internal lot line) Table 4.1: Dimensional Requirements by Zoning District MINIMUM BUILDABLE AREA (SF) AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I 24,892 24,892 24,892 24,892 17,325 (single family) 20,400 17,600 — — — — — 17,325 (two-family on one lot) 8,662 (two family dwelling on two lots/zero internal lot line) MINIMUM AREA LYING ABOVE FLOODPLAIN6 (SF) AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I With Sewer 17,0006 17,0006 17,0006 17,0006 30,0006 30,0006 17,0006 — — — — — Without Sewer 51,0006 51,0006 51,0006 51,0006 — — — — — — — — MINIMUM LOT WIDTH (FT) AG AR-3 AR R-1 R-27 R-3 M-H OIP B-1 B-2 OBP I With Sewer 100 100 100 100 125 100 100 100 100 100 100 100 Without Sewer 150 150 150 150 150 150 150 150 150 150 150 150 MAXIMUM PRINCIPAL BUILDING OR STRUCTURE HEIGHT 8 (FT) AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I 40 40 40 40 40 40 40 40 35 55 559 80 MINIMUM PRINCIPAL BUILDING SETBACK (FT)10 AG AR-3 AR R-1 R-211 R-312 M-H OIP B-1 B-2 OBP I Front (measured from ROW) From major thoroughfare 40 40 40 40 35 30 40 20 20 20 35 20 From minor street 30 30 30 30 25 25 30 15 20 15 20 15 Side 25 15 15 10 10 - 10 10 10 10 25 10 Rear 25 40 40 40 40 15 40 10 10 10 40 10 REQUIRED INCOMPATIBLE USE BUFFER (FT) (ALONG A SIDE OR REAR LOT LINE NEXT TO LESS INTENSE USE OR ZONING SHOWN BELOW) AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I Agricultural13 — — — — — 15 15 15 15 15 15 25 1- or 2-Family Residential — — — — — 25 25 25 50 50 50 100 Multi-Family — — — — — — — 25 25 25 25 50 Table 4.1: Dimensional Requirements by Zoning District Office, Institutional, Commercial, or Industrial — — — — — — — — — — — — MAXIMUM % LOT14 COVERAGE AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I — — — — — — — 70 70 80 80 90 MINIMUM FLOOR AREA PER DU: PRINCIPAL BUILDINGS15 (SF) AG AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I 1,000 1,600 (1 story) 1,600 (1 story) 1,600 (1 story) 1,600 (single family, 1 story) 1,600 (single family, 1 story) 1,000 (manufactured home subdivision or manufactured home park) — — — — — — 1,850 (2 story) 1,850 (2 stories) 1,850 (2 stories) 1,850 (single family, 2 stories) 1,850 (single family, 2 stories) — — — — — — — — — — 1,500 (two family, per DU) 1,500 (two family, per DU) — — — — — — — — — — — Multi Family: 800 (efficiency or one-bedroom) 900 (2 bedroom) 1,000 (3 bedroom) — — — — — — 1 Minimum lot size varies depending on the number of lots in a minor subdivision, refer to UDC Sec. 503. 2 See Sec. 404.01 c. for minimum lot size by Character Area Map. 3 Properties (a) which were rezoned for a major subdivision prior to July 2, 2019, shall be permitted to be developed pursuant to the approved concept plan, specifically including, without limitation, the use of the minimum lot sizes allowed under the provisions of this ordinance as of July 1, 2019, and (b) those which were subject to an enforceable legal obligation to be purchased as of July 2, 2019, and which receive preliminary plat approval on or before December 29, 2019, shall be permitted to be developed using the minimum lot sizes allowed under the provisions of this ordinance as of July 1, 2019. 4 The minimum lot size in the AR and AR-3 zoning districts may be reduced only in accordance with the provisions for Uconservations subdivisionsUand only in accordance with a conservation subdivision plan which has been approved by the Board of Commissioners. 5 Figures shown are for lots in a manufactured home subdivision. For a manufactured home park (sewer required), maximum density is 2.5 units per acre and the minimum area for each manufactured home space or stand is 17,000 sf per home; minimum site size is 10 acres. 6 Lot Area per dwelling unit. 7 Or minimum required by County Health Department, whichever is greater. 8 Figures shown are for a two-family dwelling on one lot. Minimum lot widths for a two-family dwelling on two lots shall be 1/2 the figures shown. 9 If the building height exceeds 40 feet and/or is above the capability of normal firefighting equipment, local fire officials shall certify that such building, as proposed to be located, constructed, and equipped, and particularly the upper stories, has adequate sprinkler equipment or other built-in equipment to provide fire protection. 10 Maximum building height for principal buildings may be increased up 85 feet by Special Use Approval. 11 See Sec. 410 for accessory structure setbacks. 12 Zero side yard setbacks can be permitted on individual lots with no more than two connected units. 13 No side yard setbacks required between attached units; 10 foot side yard or 20 feet of separation between buildings. 14 See separation requirements for certain uses in Article 3. 15 ;hgFor commercial developments with shared stormwater detention facilities, the average lot coverage for all parcels in the development may be used to determine compliance with maximum percent lot coverage. 16 See definition of Vfloor area, heated.V (Res. of 7-2-2019(1), Exh. A)