--- title: Oconee County Code of Ordinances, Sec. 66-270. Dry sewers and septic tanks collection: local-codes id: local-code:oconee-county/code/66-270 cite_as: Oconee County, Ga., Code of Ordinances § 66-270 canonical_url: https://georgiacommons.org/counties/oconee/code/66-270 md_url: https://georgiacommons.org/counties/oconee/code/66-270.md text_url: https://georgiacommons.org/counties/oconee/code/66-270/text source_url: https://library.municode.com/ga/oconee_county/codes/code_of_ordinances date: 2026-04-07 status: active jurisdiction: county:oconee jurisdiction_name: Oconee County county_fips: "13219" corpus_version: local-codes-oconee-county-3120a76e576b publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/oconee/code/~part-code-of-ordinances/~chapter-66/~article-ii/~division-5.md previous: https://georgiacommons.org/counties/oconee/code/66-269.md next: https://georgiacommons.org/counties/oconee/code/66-271-to-66-290.md index: https://georgiacommons.org/counties/oconee.md branch: code edition: As published by Municode, current through 2026-04-07 edition_date_kind: current_through source_publisher: Municode version_id: local-code:oconee-county/code/66-270@2026-04-07-663794eff2 --- # Oconee County Code of Ordinances, Sec. 66-270. Dry sewers and septic tanks > As published by Municode, current through 2026-04-07 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part - CODE OF ORDINANCES / Chapter 66 - UTILITIES / Article II - WATER / Division 5 - WATER AND WASTEWATER SYSTEMS (a) For new subdivisions and nonresidential properties in areas which can be connected to active sewer by gravity sewer and the county does not plan to construct additional sewers downstream of the subject property: (1) An active sewer shall be provided to all sites smaller than 80,000 square feet. (2) Septic tanks may be utilized on sites of at least 80,000 square feet if the anticipated wastewater generation for the site is no more than one equivalent residential unit per 80,000 square feet and with the approval of the health department. (3) The county may consider development of a private developer agreement or special sewer availability area. (b) For new subdivisions and nonresidential properties in areas which can be connected to active sewer and the county plans to construct additional sewers downstream of the subject property: (1) Dry sewers, constructed in accordance with the county water system policy, shall be provided to all sites smaller than 80,000 square feet which are not provided with an active sewer. (2) In all areas where dry sewers are required by this section, septic tanks shall also be provided with the approval of lot sizes and septic tank suitability from the health department. (3) Septic tanks may be utilized on sites of at least 80,000 square feet if the anticipated wastewater generation for the site is no more than one equivalent residential unit per 80,000 square feet and with the approval of the health department. (4) The county may consider development of a private developer agreement or special sewer availability area. (c) For new subdivisions and nonresidential properties in areas which cannot be connected to active sewer and the county does not plan to construct additional sewers downstream of the subject property, septic tanks may be utilized with the approval of the health department. (d) Septic tanks shall be constructed and operated in accordance with the provisions of section 66-362. ## History (Ord. of 2-4-2003, § 2-90)