(a) Requirements.

(1) All users involved in the preparation of food for commercial purposes shall provide oil/grease interceptors or traps. Additionally, any user who generates a wastewater which contains greater than the quantity of oil and grease regulated under section 66-311, and provided that the excess oil and grease is floatable and can be effectively removed in an oil/grease interceptor or trap, then such user will be required to install a grease/oil interceptor.

(2) All users whose wastewater stream is associated with unusually large quantities of grit, sand or gravel shall be required to install a sand trap. All car/truck wash systems shall be required to install sand and grease traps.

(3) The requirements of this section shall not apply to private living quarters or dwelling units.

(b) For facilities other than eating establishments.

(1) Design criteria. All sand and oil/grease interceptors used in conjunction with facilities other than eating establishments shall have a capacity that will provide not less than ten minutes nor more than 30 minutes retention time at the peak eight-hour flow rate.

Flow-through velocities shall not exceed one foot per second at the peak eight-hour flow rate.

(2) Compliance with plumbing code. All sand and oil/grease interceptors shall be sized, located and constructed in accordance with the provisions of the duly adopted county plumbing code where such parameters have not been otherwise set forth in this article.

(c) Maintenance. To the extent section 66-319 applies only to food service or food preparation establishments' grease recovery systems, all other users shall maintain all grease, oil and sand interceptors in continuously efficient operation at all times. In the maintaining of these interceptors, the user shall be responsible for the proper recovery, removal and disposal by appropriate means of the captured material, and shall maintain records of the dates and means of disposal which are subject to review by the department director. The frequency of removal shall be such as to ensure that no overflows of oil, grease or sand into the wastewater system ever results.

(d) Proper disposal of collected materials. Any removal and hauling of the collected materials not performed by the owner's employees must be performed by waste disposal firms holding current county health department waste hauler permits for restaurant grease or hazardous waste transport permits for petroleum products. Under no circumstances shall the collected materials ever be returned to the wastewater system.

History

The history line the source prints at the end of the section.

(Ord. of 2-4-2003, § 2-148)