(a) Establishment of. Users discharging "high strength" wastewater into the county wastewater system may be assessed a monetary surcharge, in addition to the normally required sewer use charges, in an amount to be calculated as shown below. A "high strength" wastewater is defined as wastewater which contains the below shown parameters in excess of the below shown monthly average concentrations: (1) Five day, 20° C biochemical oxygen demand (BOD5) of 300 milligrams per liter (mg/l), not to exceed a maximum of 500 mg/l. (2) Chemical oxygen demand (COD) of 500 milligrams per liter (mg/l), not to exceed a maximum of 1,000 mg/l (3) Total ammonia nitrogen (NH3+NH4) of 30 mg/l, not to exceed a maximum of 45 mg/l. (4) Total inorganic phosphates of 12 mg/l, not to exceed a maximum 16 mg/l. (5) Floatable oil and grease of 100 mg/l, not to exceed a maximum of 150 mg/l. The above parameters shall be determined by the utilization of the sampling and testing procedures as provided in section 66-424. The amount of the surcharge, which may be charged and assessed against all users discharging high strength wastewater into the county wastewater system, shall reflect the cost incurred by the county in handling the excess oxygen demand, ammonia, total inorganic phosphates, and floatable oil and grease. This surcharge shall include a proportionate share of charges for maintenance and operation of the wastewater treatment facilities including depreciation and other incidental expenses. (b) Formula. When the concentrations of the surcharged parameters shown above exceed the values of the constituents as set forth in subsection (a) of this section, the excess concentrations may be subject to a surcharge in the amount derived in accordance with the following formula: Surcharge $/month P × G × 8.34 × C Where: "P" is the excess monthly average concentration in mg/l of the parameter (BOD5, etc.) being evaluated; i.e., the actual concentration less the allowable concentration listed in subsection (a) of this section would be the excess. The maximum concentration shown in subsection (a) of this section shall not be exceeded. "G" is equal to the user's total monthly wastewater flow in millions of gallons. "8.34" pounds per gallon conversion factor. "C" is equal to the unit cost in dollars per pound ($/lb) for the treatment of the surcharged parameters. This value shall be established by the director based on actual wastewater treatment costs which shall be revised from time to time as necessary. (c) Quantitative measurement of surchargeable parameters. The measurement of the surcharge parameters (BOD5, COD, ammonia, total inorganic phosphates, or floatable oil and grease) shall be conducted as follows: (1) Monitoring to determine surcharge shall be conducted by the industrial user as specified in the user's permit except that frequency of testing for surchargeable parameters shall be a minimum of two tests per month. If the permit requires more frequent testing, then the average of all test results will be used to calculate the surcharge. If the permit requires less frequent testing for compliance purposes, then testing frequency will be increased to twice per month. (2) The county may sample the user as often as desired at the county's expense. The county will split the sample with the industrial user at the user's request. (d) Billing procedure. Wastewater surcharges as provided for in this section will be included on the user's regular water and sewer bill or on a separate wastewater surcharge bill.