Skip to content
Georgia Commons
Menu

Oconee County · Code of Ordinances

Part - CODE OF ORDINANCES / Chapter 66 - UTILITIES / Article II - WATER / Division 2 - BACKFLOW PREVENTION

Sec. 66-51. Definitions.

About this text

  • As published by Municode, current through 2026-04-07
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

The following words, terms and phrases, when used in this division, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning:

Air gap separation means the unobstructed vertical distance through the atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. An approved air-gap separation shall be at least double the diameter of the supply pipe. In no case shall the air gap separation be less than one inch.

Approved, in reference to backflow prevention assemblies or methods, means those assemblies or methods which have been accepted by the director as an effective means or method to prevent backflow.

Backflow means any flow of water, liquid, gas or other substances, or any combination thereof, into the distribution piping of a potable water supply from any source or sources.

Backflow prevention assembly means an approved assembly or method used to prevent backflow from occurring in the potable water supply.

Backpressure backflow means backflow caused by a pump, elevated tank, boiler, or other means that could create pressure within the system greater than the supply pressure.

Backsiphonage backflow means a reversal of the normal direction flow in the pipeline due to a negative pressure (vacuum) being created in the supply line with the backflow source subject atmospheric pressure.

Certified tester means a person who has proven his competency to test, repair, overhaul and prepare reports on backflow prevention assemblies as evidenced by certification of successful completion of a training program approved by the director.

Consumer/customer means any person using or receiving water from the county utility department.

Containment means prevention of possible contamination from a private water system by installing an approved backflow prevention assembly.

Contamination means the degradation of the quality of water so as to constitute a hazard or impair the usefulness of water.

Cross connection means any physical connection between the county's water supply system and any other source. This includes piping systems, sewer fixtures, containers, or devices whereby water or other liquids, mixtures, or substances may flow into or enter the county's water supply system.

Cross connection inspector means an employee of the county utility department designated by the director to administer and enforce the provisions of this division.

Degree of hazard means derived from an evaluation of the health risks, system, plumbing, or pollution hazards.

Director means the director of the county utility department.

Double check-detector checkvalve assembly means an assembly composed of an approved double checkvalve assembly with a bypass water meter. The meter shall register accurately for very low flow rates and shall register all flow rates.

Double checkvalve assembly means an assembly composed of two single, independently acting approved checkvalves, including tightly closing shutoff valves located at each end of the assembly, and suitable connections for testing the watertightness of each checkvalve.

High hazard means an actual or potential threat of contamination to the public water system or to a private water system to such a degree or intensity that there could be a danger to health.

Imminent hazard means an actual threat of contamination that presents a danger to the public health with consequences of serious illness or death.

Moderate hazard means one that presents foreseeable and significant potential for pollution, nuisance, aesthetically objectionable, or other undesirable alterations of the drinking water supply.

Owner means any person owning fee simple interest in property served by the county utility department.

Point of delivery means the terminal end of a service connection from the public potable water system, i.e., where the director loses sole jurisdiction over the water; the point where water leaves the public water system and enters a private water system. This point is defined physically as the connection or coupling on the outlet of the water meter or the inlet flange of an approved backflow prevention device on an unmetered fire service connection.

Potable water means water from any source which has been approved for human consumption by the state environmental protection division (EPD).

Private water system means a system of pipes or other associated facilities that is not part of the county's public water system and is used to move or receive water, regardless of the source of water in such system.

Reduced pressure principle assembly means an assembly containing within its structure a minimum of two independently acting, approved checkvalves, together with an automatically operating pressure differential relief valve located between the checkvalves. The first checkvalve reduces the supply pressure a predetermined amount so that during normal flow and at cessation of normal flow, the pressure between the checks shall be less than the supply pressures. In case of leakage of either checkvalve, the differential relief valve, by discharge to the atmosphere, shall operate to maintain the pressure between the checks less than the supply pressure. The assembly must include properly located test cocks and tightly closing shutoff valves at each end of the assembly.

Reduced pressure principle-detector assembly means an assembly composed of an approved reduced pressure principle backflow prevention assembly with a bypass water meter. The meter shall register accurately for very low flow rates and shall register all flow rates.

Standards means official printed standards for water and wastewater systems for the county utility department adopted by the board of commissioners.

Water supply (approved) means any public potable water supply which has been investigated and approved by the state environmental protection division (EPD). The system must be operating under a valid permit.

History

The history line the source prints at the end of the section.

(Ord. of 2-1-2000, § 1.02)