--- title: Oglethorpe County Code of Ordinances, Sec. 24-27. Culverts and pipe collection: local-codes id: local-code:oglethorpe-county/code/24-27 cite_as: Oglethorpe County, Ga., Code of Ordinances § 24-27 canonical_url: https://georgiacommons.org/counties/oglethorpe/code/24-27 md_url: https://georgiacommons.org/counties/oglethorpe/code/24-27.md text_url: https://georgiacommons.org/counties/oglethorpe/code/24-27/text source_url: https://library.municode.com/ga/oglethorpe_county/codes/code_of_ordinances date: 2026-09-14 status: active jurisdiction: county:oglethorpe jurisdiction_name: Oglethorpe County county_fips: "13221" corpus_version: local-codes-oglethorpe-county-9e77fd875fbd publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/oglethorpe/code/~chapter-24/~article-ii/~division-1.md previous: https://georgiacommons.org/counties/oglethorpe/code/24-26.md next: https://georgiacommons.org/counties/oglethorpe/code/24-28.md index: https://georgiacommons.org/counties/oglethorpe.md branch: code edition: As published by Municode, current through 2026-09-14 edition_date_kind: current_through source_publisher: Municode version_id: local-code:oglethorpe-county/code/24-27@2026-09-14-ad0d9560a3 --- # Oglethorpe County Code of Ordinances, Sec. 24-27. Culverts and pipe > As published by Municode, current through 2026-09-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Chapter 24 / Article II - SUBDIVISION ROAD CONSTRUCTION AND MAINTENANCE / Division 1 - GENERALLY (a) Pipe size shall be determined by standard engineering practice. The developer will provide drainage areas on the plat. All pipe shall be galvanized bituminous coated, aluminized, galvanized or concrete and shall be obtained from a DOT-approved supplier. Cross drain pipe smaller than 18 inches in diameter shall not be used, including entrances to subdivisions on existing roadways and side streets. One of the following materials shall be used at the ends of cross drain pipe: Flared end sections (except on pipe 30 inches or larger), stone dumped rip-rap, sand bag rip-rap or concrete headwalls according to optical carrier standards and details. Safety flared end sections or safety grates on headwalls shall be used on cross drain pipes at subdivision entrances and other roads or streets along roadways with speed limit of 45 miles per hour or greater. (b) A flared end section shall be attached to the inlet and outlet of side drain pipes. Pipe less than 15 inches in diameter shall not be used. Plastic pipe (15 inches or larger) may be used for driveways only. Driveways should be constructed to divert water into drainage ditches or away from the road according to the county driveway regulations. (Code 2008, § 22-104) O.C., Rev. CD24:5