--- title: Oglethorpe County Code of Ordinances, Sec. 24-54. Compaction collection: local-codes id: local-code:oglethorpe-county/code/24-54 cite_as: Oglethorpe County, Ga., Code of Ordinances § 24-54 canonical_url: https://georgiacommons.org/counties/oglethorpe/code/24-54 md_url: https://georgiacommons.org/counties/oglethorpe/code/24-54.md text_url: https://georgiacommons.org/counties/oglethorpe/code/24-54/text source_url: https://library.municode.com/ga/oglethorpe_county/codes/code_of_ordinances date: 2026-09-14 status: active jurisdiction: county:oglethorpe jurisdiction_name: Oglethorpe County county_fips: "13221" corpus_version: local-codes-oglethorpe-county-9e77fd875fbd publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/oglethorpe/code/~chapter-24/~article-ii/~division-2.md previous: https://georgiacommons.org/counties/oglethorpe/code/24-53.md next: https://georgiacommons.org/counties/oglethorpe/code/24-55-to-24-81.md index: https://georgiacommons.org/counties/oglethorpe.md branch: code edition: As published by Municode, current through 2026-09-14 edition_date_kind: current_through source_publisher: Municode version_id: local-code:oglethorpe-county/code/24-54@2026-09-14-3fe5850ca6 --- # Oglethorpe County Code of Ordinances, Sec. 24-54. Compaction > As published by Municode, current through 2026-09-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Chapter 24 / Article II - SUBDIVISION ROAD CONSTRUCTION AND MAINTENANCE / Division 2 - PAVING (a) Testing performed. Compaction tests shall be performed on the following materials at the following intervals: (1) Grading. One compaction test shall be required in each fill section two feet in depth or greater regardless of length and one test is required every 500 feet in fill sections longer than 500 feet. A compaction test shall be required within every four feet of fill or portion thereof for fills greater than four feet. Fill material shall be compacted to at least 95 percent of the maximum density. (2) Sub-grade. One compaction test shall be required every 500 feet of sub-grade. The sub-grade shall be compacted to 100 percent of the maximum density. (3) Base. For aggregate base material, a compaction test shall be required every 500 feet. Aggregate base shall be compacted to 100 percent of the maximum density. Asphaltic concrete base shall be compacted to at least 98 percent of the maximum density. (4) Paving. For asphaltic concrete paving, a compaction test shall be required every 500 feet. Asphaltic concrete paving shall be compacted to at least 98 percent of the maximum density. (b) Areas not meeting compaction test specifications. Any areas that do not meet with the specified compaction shall be excavated and replaced with suitable material. Test results shall be submitted to the chairman of the board of commissioners or the chairman's designee, as appropriate. The developer shall incur all costs for compaction tests. ## History (Code 2008, § 22-102)