Skip to content
Georgia Commons
Menu

Paulding County · Code of Ordinances

Part II - CODE OF ORDINANCES / Chapter 18 - BUILDINGS AND BUILDING REGULATIONS / Article III - PERMITS AND INSPECTIONS / Division 1 - GENERALLY

Sec. 18-67. Drawings and specifications.

About this text

  • As published by Municode, current through 2025-12-09
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Requirements. Two or more, as requested, full sets of plans plus a complete electronic set in one Portable Document Format (PDF) of specifications, and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work, shall accompany the application for a permit. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the technical codes. Such information shall be specific, and the technical codes shall not be cited as a whole or in part, nor shall the term legal or its equivalent be used, as a substitute for specific information. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design.

(b) Additional data. The county building official may require details, computations, stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations. All drawings, specifications and accompanying data required by the county building official to be prepared by an architect or engineer shall be affixed with their official seal.

(c) Design professional. The design professional shall be an architect or engineer legally registered under state law that regulate the practice of architecture or engineering and shall affix his official seal to such drawings, specifications and accompanying data, for the following:

(1) All Group A, E and I occupancies;

(2) Buildings and structures three stories or more high;

(3) Buildings and structures 5,000 square feet (465 m2 ) or more in area.

For all other buildings and structures, the submittal shall bear the certification of the applicant that some specific state law exception permits its preparation by a person not so registered. Exception: Single-family dwellings, regardless of size, shall require neither a registered architect or engineer, nor a certification that an architect or engineer is not required.

(d) Structural and fire resistance integrity. Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistance wall, floor or partition will be made for electrical, gas, mechanical, plumbing, signal and communication conduits, pipes and systems and also indicate in sufficient detail how the fire integrity will be maintained where required fire resistance floors intersect the exterior walls.

(e) Site drawings. Drawings shall show the location of the proposed building or structure and of every existing building or structure on the site or lot. The county building official may require a boundary line survey prepared by a qualified surveyor.

(f) Hazardous occupancies. The county building official may require the submission of a general site plan drawn at a legible scale which shall include, but not be limited to, the location of all buildings, exterior storage facilities, permanent access ways, evacuation routes, parking lots, internal roads, chemical loading areas, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment and adjacent property uses. The exterior storage areas shall be identified with the hazard classes and the maximum quantities per hazard class of hazardous materials stored. The county building official may also require the submission of a building floor plan drawn to a legible scale which shall include, but not be limited to, all hazardous materials storage facilities within the building and shall indicate rooms, doorways, corridors, exits, fire rated assemblies with their hourly rating, location of liquid tight rooms, and evacuation routes. Each hazardous materials storage facility shall be identified on the plan with the hazard classes and quantity range per hazard class or the hazardous materials stored.

History

The history line the source prints at the end of the section.

(Res. No. 99-14, § 7, 2-9-1999; Ord. No. 19-03, § 2, 7-23-2019)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:paulding-county/code/18-67@2025-12-09-ee8e1e8e6d

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Paulding County Code of Ordinances, Sec. 18-67. Drawings and specifications | Georgia Commons