--- title: Paulding County Code of Ordinances, 604.4.2.2. Cooling Towers and Evaporative Coolers. Cooling towers collection: local-codes id: local-code:paulding-county/code/604.4.2.2 cite_as: Paulding County, Ga., Code of Ordinances ยง 604.4.2.2 canonical_url: https://georgiacommons.org/counties/paulding/code/604.4.2.2 md_url: https://georgiacommons.org/counties/paulding/code/604.4.2.2.md text_url: https://georgiacommons.org/counties/paulding/code/604.4.2.2/text source_url: https://library.municode.com/ga/paulding_county/codes/code_of_ordinances date: 2025-12-09 status: active jurisdiction: county:paulding jurisdiction_name: Paulding County county_fips: "13223" corpus_version: local-codes-paulding-county-bd4ed03a5061 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/paulding/code/~part-ii/~chapter-18/~article-ii.md previous: https://georgiacommons.org/counties/paulding/code/604.4.2.1.md next: https://georgiacommons.org/counties/paulding/code/604.4.3.1.md index: https://georgiacommons.org/counties/paulding.md branch: code edition: As published by Municode, current through 2025-12-09 edition_date_kind: current_through source_publisher: Municode version_id: local-code:paulding-county/code/604.4.2.2@2025-12-09-afda605b57 --- # Paulding County Code of Ordinances, 604.4.2.2. Cooling Towers and Evaporative Coolers. Cooling towers > As published by Municode, current through 2025-12-09 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 18 - BUILDINGS AND BUILDING REGULATIONS / Article II - TECHNICAL CODES and evaporative coolers shall be equipped with makeup water and blow down meters, conductivity controllers and overflow alarms. Cooling towers shall be equipped with efficiency drift eliminators that achieve drift reduction to 0.002 percent of the circulated water volume for counterflow towers and 0.005 percent for crossflow towers. 604.4.2.3 Cooling Tower Makeup Water. Water used for air conditioning, cooling towers shall not be discharged where the hardness of the basin water is less than 1500 mg/L. Exception: Where any of the following conditions of the basin water are present: total suspended solids exceed 25 ppm, CaCO3 exceeds 600 ppm, chlorides exceed 250 ppm, sulfates exceed 250 ppm, or silica exceeds 150 ppm. 604.4.3 Landscape Irrigation System Efficiency Requirements. The requirements in Section 604.4.3 apply to all new landscape irrigation systems connected to the public water system except those (a) used for agricultural operations as defined in the Official Code of Georgia Section 1-3-3, (b) used for golf courses, and (c) dependent upon a nonpublic water source. Nothing in this Code or this Section 604.4.3 is intended to require that landscape irrigation systems must be installed at all premises. The landscape irrigation efficiency requirements in this Section 604.4.3 apply only when someone voluntarily chooses, or is otherwise required by some requirement beyond this Code, to install a landscape irrigation system on premises.