--- title: Polk County Code of Ordinances, Sec. 55-7. Marking and lighting unserviceable areas including closed runways and taxiways collection: local-codes id: local-code:polk-county/code/55-7 cite_as: Polk County, Ga., Code of Ordinances § 55-7 canonical_url: https://georgiacommons.org/counties/polk/code/55-7 md_url: https://georgiacommons.org/counties/polk/code/55-7.md text_url: https://georgiacommons.org/counties/polk/code/55-7/text source_url: https://library.municode.com/ga/polk_county/codes/code_of_ordinances date: 2026-06-02 status: active jurisdiction: county:polk jurisdiction_name: Polk County county_fips: "13233" corpus_version: local-codes-polk-county-734ee1619160 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/polk/code/~chapter-55.md previous: https://georgiacommons.org/counties/polk/code/55-6.md next: https://georgiacommons.org/counties/polk/code/55-8.md index: https://georgiacommons.org/counties/polk.md branch: code edition: As published by Municode, current through 2026-06-02 edition_date_kind: current_through source_publisher: Municode version_id: local-code:polk-county/code/55-7@2026-06-02-10445f52ca --- # Polk County Code of Ordinances, Sec. 55-7. Marking and lighting unserviceable areas including closed runways and taxiways > As published by Municode, current through 2026-06-02 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Chapter 55 - AIRPORT RULES AND REGULATIONS (a) Generally. Applications of the standards and practices contained in the appropriate FAA Advisory Circular, Marking of Paved Areas on Airports, as amended or superseded, apply when there is a closed or hazardous area on the airport or when a deceptive area exists and the airport manager determines that an operational need exists to mark same. Replace or modify as soon as possible existing markings that are not in the advisory circular. (b) Hazardous and unserviceable parts of the air operations area. (1) Where a relatively small paved area has failed or for any other reason becomes hazardous for aircraft operation and it is not intended to close the entire area to operations, use red flags not less than 18 inches square for day marking and use red lights or lighted barricades with flags for night marking to delineate the hazardous area. When flags are made of fabric, use a wire stiffener to hold the flag in an extended position. Mount flags so they are not a hazard. (2) Where large apron areas are unserviceable, place a cross, as shown by the appropriate FAA advisory circular, in the center of the unserviceable area. If this type movement area is used at night, place red lights to delineate the unserviceable parts of the area. (3) On runways or taxiways where the unserviceable area is such as to render the runway or taxiway or portion thereof unusable, place red lights at the entrance to such areas and disconnect controls to the runway or taxiway lights in the section rendered unusable. (4) Use red lights of at least ten candlepower for night marking of unserviceable parts of the movement areas. Red lights with a light distribution equivalent to a fixture meeting the requirements in AC 150/5345-2, Specification for L-180 Obstruction Light, are acceptable. (c) Closed airports. When the entire air operations area is rendered unsafe by a hazardous condition, declare the field closed and mark as follows: (1) Day marking. Place a cross over runway numbers readily visible from the air. Make all crosses in accordance with the current FAA Advisory Circular AC 150/5340-1 as amended or superseded, Marking of Paved Areas on Airports, as amended or superseded. (2) Night marking. Disconnect controls to runway, taxiway, lighted wind cone and rotating beacon lights. (d) Color. Use aviation yellow for all deceptive, closed, and hazardous area markings. (e) Notification. Immediately report closed runways and taxiways, airport hazardous areas and closed airports to the Atlanta Flight Service Station (404-691-1474). (f) Safety during construction. These guidelines apply to all construction work, which may affect the movement of aircraft. (1) Prior to the development of contract specifications for construction activity affecting aircraft movement areas, safety requirements relating thereto should be coordinated between the airport management and appropriate representatives of the FAA to determine the restrictions required for the project's special provisions, which should result in a minimum of interference to aircraft operations. (2) For construction activity to be performed in other than active operational areas, the storage and parking of equipment and materials when not in use or about to be installed should not encroach upon active operational areas. The protection of operational areas shall be in accordance with the current FAA AC 150/5300-13, Airport Design, as amended or superseded. (3) Open-flame, welding, or torch cutting operations are to be prohibited, unless adequate fire and safety precautions have been made and approved by the county or its designee. (4) Open trenches, excavations, and stockpiled material at the construction-site will be prominently marked with red flags and lighted by red light units (acceptable to the airport manager) during hours of restricted visibility and/or darkness. (5) All vehicles will be clearly identified for control purposes, by assigned number prominently displayed on each side. The identifying symbols should be eight-inch minimum, block-type characters of a color easily read on a contrasting background. They may be applied by use of tape or water-soluble paint to facilitate removal. (6) All vehicles will follow routes and roadways selected by the airport manager or his representative and stay clear of areas adjacent to NAVAIDS that if traversed could cause emission of false signals or failure of NAVAIDS. These sensitive areas will be identified and clearly marked by the airport engineer. (7) The airport engineer will identify and mark with yellow flags the location of all utilities in the construction areas that if interrupted, could cause failure of a facility or NAVAID. (8) The airport manager will issue the necessary notices to airmen, (NOTAMs), to reflect hazardous conditions. NOTAMs will be kept current and reflect the actual condition with respect to construction situations, active NOTAMs will be reviewed periodically. (9) Frequent inspections will be made by the airport manager during critical phases of the work to insure that the contractor is following the recommended safety procedures. ## History (Ord. of 9-14-2010, § 6; Ord. No. 2020-16, § 2, 4-7-2020)