Underground utilities, including sewer services, all water lines, and any cable conduits under the pavement shall be placed in the ground before the base material is in place. All trenches shall be thoroughly compacted in six-inch (6") layers with mechanical compacting equipment. All fire hydrants, utility poles, street lights, transformer boxes and pedestals shall be set at a distance not less than six feet (6') from the back of the curb.