--- title: Pulaski County Code of Ordinances, Section 5.2.12. Selection Guidelines for Storm Sewer Piping collection: local-codes id: local-code:pulaski-county/code/5.2.12 cite_as: Pulaski County, Ga., Code of Ordinances ยง 5.2.12 canonical_url: https://georgiacommons.org/counties/pulaski/code/5.2.12 md_url: https://georgiacommons.org/counties/pulaski/code/5.2.12.md text_url: https://georgiacommons.org/counties/pulaski/code/5.2.12/text source_url: https://library.municode.com/ga/pulaski_county/codes/code_of_ordinances date: 2023-06-05 status: active jurisdiction: county:pulaski jurisdiction_name: Pulaski County county_fips: "13235" corpus_version: local-codes-pulaski-county-c364c75aa37b publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/pulaski/code/~appendix-a/~chapter-5.md previous: https://georgiacommons.org/counties/pulaski/code/5.2.11.md next: https://georgiacommons.org/counties/pulaski/code/5.3.1.md index: https://georgiacommons.org/counties/pulaski.md branch: code edition: As published by Municode, current through 2023-06-05 edition_date_kind: current_through source_publisher: Municode version_id: local-code:pulaski-county/code/5.2.12@2023-06-05-de287f697d --- # Pulaski County Code of Ordinances, Section 5.2.12. Selection Guidelines for Storm Sewer Piping > As published by Municode, current through 2023-06-05 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - SUBDIVISION ORDINANCE / Chapter 5 - CONFORMANCE WITH COMPREHENSIVE PLAN, IMPROVEMENTS REQUIRED, DESIGN AND CONSTRUCTION STANDARDS FOR ALL SUBDIVISIONS / 5.0 - Conformance With Comprehensive Plan and Other Regulations. Type of Pipe Installation Reinforced Concrete Pipe (RCP) Corrugated Steel AASHTO M-36 Corrugated Aluminum AASHTO M-196 Plastic AASHTO M-294 Reinforced Concrete Box Culvert Per GADOT Standards Aluminized Type II CMP Bituminous Coated CMP Aluminum Alloy CMP Corr. High Density Polyethylene Smooth Lined Longitudinal Grade < 10% Yes Yes Yes Yes Yes (1) NA Longitudinal Grade > 10% No Yes Yes Yes Yes (1) NA Cross Drain < 250 ADT Yes Yes Yes Yes Yes (1) NA Cross Drain > 250 ADT Yes No No No No NA Cross Drain Flowing Stream Appl. Yes 3 No Yes Yes (1) (4) NA Cross Drain 25 Yr. Flow > 200 CFS or Fill Depth > 18 ft. 2 No No No No Yes Conditional Uses: 1. Corrugated high-density polyethylene pipe, smooth lined type "S", must be manufactured and installed in strict compliance with the manufacturer's recommendation. Special backfill and bedding are required per the direction of the County Roads Superintendent. Prior approval of the County Roads Superintendent is required. HDPE applications shall not exceed 36" diameter. 2. Reinforced concrete box culverts are required under excessive flow and/or fill depth conditions. Approved pipe materials may be utilized in some instances, based on the County Roads Superintendent's assessment of existing conditions and future maintenance requirements. 3. The addition of Type "A" full bituminous coating, with paved invert, is required for this application. (AASHTO M-190) 4. Requires approval of County Roads Superintendent based on assessment of existing conditions and future maintenance requirements. Section 5.3 Design Standards.