(a) Grading. All streets, roads and alleys shall be graded by the subdivider to provide the necessary paving, roadway, drainage and safety requirements. (b) Storm drainage. An adequate drainage system, including necessary curbs, pipes, culverts, headwalls and ditches as appropriate, shall be provided for the proper drainage of all surface water. Pipe size will be determined by the use of the rational method or the peak discharge method. (c) Installation of utilities. After grading is completed and before any base is applied, all of the underground utilities (water mains, sewer mains, gas mains, and all related service connections) shall be installed completely throughout the length of the street; and all driveways for houses to be built by the subdivider shall be cut and drained. (d) Slopes and shoulder improvements. The minimum ratio for all fill or cut slopes (including drainage ditches) shall be 2:1; and the minimum width for all shoulders from back edge of the curb, if installed, shall be eight feet. All shoulders shall slope one-half inch to the foot. When all construction is completed, all slopes and shoulders shall be cleared of all rubbish and shall have a stand of grass to prevent undue erosion, either by sprigging or seeding.