(a) Each commercial and multifamily application for a permit shall be accompanied by two sets of plans and specifications, except as outlined in section 18-75. (b) All plans for buildings, structures, additions or alterations to group E-educational, group I-institutional, and group A-assembly occupancy, regardless of size, and all buildings or structures three or more stories in height or greater than 5,000 square feet in area (except those classified as one-family and two-family dwellings, expressly exempted by the chief building inspector, and those buildings or structures for farm or agricultural purposes), such designer shall be an architect or engineer legally registered under the laws of the state regulating the practice of architecture or engineering, and shall affix his official seal to such plans, specifications and accompanying data. (c) Plans shall be original drawings or prints of the structure, mechanically reproduced at the original scale on substantial paper, showing completely all foundations, wall sections, floor plans, roof plans and elevations at a convenient scale; a plot plan showing the actual shape and dimensions of the lot to be built upon; the exact sizes and location on the lot of the buildings or structures to be erected or altered, the location and number of required off-street parking and loading spaces; such other information as may be required to determine compliance with the building code and this chapter; complete structural, mechanical, plumbing and electrical plans; and such other reasonable information as may be required to clearly show the nature, character and location of the proposed work. Computations, stress diagrams, shop drawings, floor plans of existing buildings to which additions are proposed and other data necessary to show compliance with the building code shall be included when required by the planning and development department. Any specifications in which general expressions are used to the effect that "work shall be done in accordance with the building code" or "to the satisfaction of the of the planning and development department," shall be deemed imperfect and incomplete, and every reference to the building code shall be by section or subsection number applicable to the materials to be used, or to the methods of construction proposed. (d) With respect to commercial and multifamily, the director may authorize the issuance of a permit without plans and specifications for minor alterations, repairs and small or unimportant work, but in no instance where the work is of a structural nature. The issuance of a permit without plans and specifications will still require the necessary inspections and compliance with the building code and all other pertinent regulations. (e) It shall be unlawful to use roof or wall covering material that has not been approved by the applicable building code as exterior covering material except in the event a building is damaged by natural or manmade disaster, or suffers a roof leak, other leak, or other damage. In such cases, temporary materials may be applied to a building to provide a temporary repair for no more than 60 days from the date of the damage. One 60-day extension can be requested from the director, for cause, if the structure is not able to be properly repaired with approved exterior covering material within 60 days. Examples of materials that are not approved as exterior covering materials include, but are not limited to, tarpaulins, plastic sheeting, and OSB. This restriction shall not apply to [a] building, such as outbuildings and storage buildings.