(a) Sampling procedures. When wastewater sampling is required by the county of any user for any purpose, the following sampling procedures shall be utilized: (1) Except as indicated in subsection (2) below, the user must collect wastewater samples using 24-hour flow-proportional composite collection techniques where feasible. In the event flow-proportional sampling is infeasible, samples may be obtained through 24-hour time-proportional composite sampling or through a minimum of four grab samples where the user demonstrates that this will provide a representative sample of the effiuent being discharged. Samples shall be taken of increments of not more than one hour, properly refrigerated and composited in proportion to the flow for a representative sample. The frequency of sampling, sampling chamber, metering device, sampling methods, and analysis of samples shall be subject, at any time, to inspection and verification by the county. Sampling and measuring facilities shall be such as to provide safe access for authorized personnel of the county for making such inspection and verification. (2) Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques. (b) Testing procedures. (1) All wastewater monitoring samples required by the county shall be tested by an independent laboratory for the parameters required, with the results submitted to the county on the original laboratory report sheets signed by an authorized company representative. The requirement for utilization of an independent laboratory may be waived by the county when the required tests are performed by the county or other approved agency or when duplicate ("split") samples are provided to the county and the county's testing results of such duplicate samples show a reasonably good correlation with the user's in-house testing results. (2) All measurements, tests, and analyses of the characteristics of waters and wastes to which reference is made in this chapter shall be performed in accordance with the techniques prescribed in 40 CFR Part 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 CFR 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance with procedures approved by EPA.