Sec. 98-45. Landscape irrigation system efficiency requirements.
About this text
- As published by Municode, current through 2026-01-27
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The requirements in section 98-45 apply to all new landscape irrigation systems connected to the public water system except those (a) used for agricultural operations as defined in the O.C.G.A.
§ 1-3-3, (b) used for golf courses, and (c) dependent upon a nonpublic water source. Nothing in this Code or this section 98-45 is intended to require that landscape irrigation systems must be installed at all premises. The landscape irrigation efficiency requirements in this section 98-45 apply only when someone voluntarily chooses or is otherwise required by some requirement beyond this Code, to install a landscape irrigation system on-premises.
(1) Avoiding Water Waste through design.
All new landscape irrigation systems shall adhere to the following design standards:
a. Pop-up type sprinkler heads shall pop up to a height above vegetation level of not less than four inches above the soil level when emitting water,
b. Pop-up spray heads or rotary sprinkler heads tnust direct flow away from any adjacent surfaces and must not be installed closer than four inches from impervious surfaces.
c. Areas less than ten feet in width in any direction shall be irrigated with subsurface irrigation or by other means that produce no overspray or runoff.
d. Narrow or irregular shaped landscaped areas, less than four feet in any direction across opposing boundaries shall not be irrigated by any irrigation emission device
except sub-surface or low flow emitters with flow rates not to exceed
6.3 gallons per hour.
(2) Landscape irrigation system required components. All new landscape irrigation systems shall include the following
components:
a. A rain sensor shut-off installed in an area that is unobstructed by trees, roof overhangs, or anything else that might block rain from triggering the rain sensor shutoff.
b. A master shut-off valve for each controller is installed as close as possible to the point of connection of the water but downstream of the backflow prevention assembly.
c. Pressure-regulating devices such as valve pressure regulators, sprinkler head pressure regulators, inline pressure regulators, Water Sense spray sprinkler bodies or other devices
shall be installed as needed to achieve the manufacturer's recommended pressure range at the emission devices for optimal performance.
d. Except for landscape irrigation systems serving a single-family home, all other systems must also include:
1. A Water Sense irrigation controller; and
2. At feast one flow sensor, which must be installed at or near the supply point of the landscape irrigation system and shall interface with the control system, when connected to the Water Sense controller will detect and report high flow conditions to such controller and automatically shut master valves. The flow sensor serves to aid in detecting leaks or abnormal flow conditions by suspending irrigation. High flow conditions should be consistent with manufacturers' recommendations and specifications.
History
(Ord. No. O-2024-36, Part I, 12-10-2024)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.