Screven County · Code of Ordinances
Part II - CODE OF ORDINANCES / Chapter 26 / Article III - GROUNDWATER RECHARGE AREA PROTECTION
Sec. 26-77. Groundwater protection standards.
About this text
- As published by Municode, current through 2021-06-08
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) For all pollution susceptibility areas, new waste disposal facilities must have synthetic liners and leachate collection systems.
(b) New agricultural impoundments shall meet the following requirements:
(1) For areas of high susceptibility, a liner shall be provided that is approved by the U.S.
Soil Conservation Service (SCS).
(2) For areas of medium susceptibility, an SCS-approved liner shall be provided if the site exceeds 15 acre-feet.
(3) For areas of low susceptibility, an SCS-approved liner shall be provided if the site exceeds 50 acre-feet.
(c) No land disposal of hazardous waste shall be permitted within any significant groundwater recharge area.
(d) For all significant groundwater recharge areas, the handling, storage and disposal of hazardous materials shall take place on an impermeable surface having spill and leak protection approved by the state department of natural resources, environmental protection division (EPD).
(e) For all significant groundwater recharge areas, new aboveground chemical or petroleum storage tanks larger than 650 gallons must have secondary containment for 100 percent of tank volume or 110 percent of the largest tanks in a cluster of tanks.
(f) For high pollution susceptibility areas, new wastewater treatment basins shall have an impermeable liner approved by the environmental protection division.
(g) For high pollution susceptibility areas, no new stormwater infiltration basins may be constructed.
(h) For high pollution susceptibility areas, wastewater spray irrigation systems or the land spreading of wastewater sludge shall be practiced in accordance with department of natural resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land spreading of wastewater sludge must be accompanied by proof that the applicant has received a land application system permit from environmental protection division.
(i) Minimum lot sizes and septic systems. New homes served by septic tank/drain systems shall conform to minimum lot size requirements identified in tables 1—3 as follows:
TABLE 1. Minimum Lot-Size Requirements. Source: DHR Manual for On-Site Sewerage Management Systems
Pollution Susceptibility New Homes Served by Septic Systems New Mobile Homes Served by Septic Systems High 150% of minimum lot sizes specified in Table 2 150 percent of minimum lot sizes specified in Table 3 Medium 125% of minimum lot sizes specified in Table 2 125% of minimum lot sizes specified in Table 3 Low 110% of minimum lot sizes specified in Table 2 110% of minimum lot sizes specified in Table 3 TABLE 2. Single Family Home Minimum Lot Size where served by On-Site Septic Tank Systems. Source: DHR Manual for On-Site Sewerage Management Systems.
Slope of Soil Grouping (See Appendix) Lot (percent) 12345 Minimum Lot Size in Square Feet 0—5 30,000 39,000 48,000 51,000 60,000 5—15 33,000 42,000 51,000 54,000 66,000 15—25 36,000 45,000 54,000 57,000 N/A 25—35 39,000 48,000 57,000 60,000 N/A TABLE 3. Mobile Home Minimum Lot Size where served by On-Site Septic Tank Systems.
Source: DHR Manual for On-Site Sewerage Management Systems.
Slope of Soil Grouping (See Appendix) Lot (percent) 12345 Minimum Lot Size in Square Feet 0—5 10,000 13,000 16,000 17,000 20,000 5—15 11,000 14,000 17,000 18,000 22,000 15—25 12,000 15,000 18,000 19,000 N/A 25—35 13,000 16,000 19,000 20,000 N/A (Ord. No. 99-07, § 5, 6-8-1999)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.