(a) Utility connections. All new manufactured homes must be permanently connected to water, sewer, and electrical service.
(1) Water. Water service may be public or private. Connection procedures must meet the requirements of the Southern Standard Plumbing Code, as adopted in the state, and must be freeze proof above and below the ground.
(2) Sewer. Plumbing for the sewer or septic system must be approved by the county health department.
(3) Electrical. Electrical service must meet requirements of the most recent National Electrical Code.
(b) Foundation. Unless placed on a permanent foundation, all manufactured homes must be installed in accordance with the "Installation of Manufactured and Mobile Homes" rules and regulations, established and published by the state safety fire commissioner (O.C.G.A.
§ 8-2-16 et seq.), installed with permanent skirting, secured with tiedown devices and provided with steps and landings. The installation of all required foundation requirements must be inspected and approved by the building official.
(c) Skirting. Installation of skirting shall be required. Installation shall be in accordance with the manufacturer's installation instructions. Acceptable materials may include masonry, stone, metal, vinyl, or other materials manufactured for the purpose of skirting.
(d) Tiedown. Each manufactured home shall have tiedowns or other devices securing the stability of the manufactured home as per "Installation of Manufactured Homes and Mobile Homes" rules and regulations, established and published by the state safety fire commissioner (O.C.G.A. § 8-2-160 et seq.).
(e) Steps and landings. Steps and landings are required for all homes and shall be constructed to the standards set forth in chapter XI, section 1113, stairway construction, of the Standard Building Code; provided, however, that landings shall not be smaller than 36 inches wide and 48 inches deep.
(f) Recreational vehicles. Permanent connection of recreational vehicles to water, sewer, or electrical service is prohibited. Installation of recreational vehicles on piers and jacks permanently is also prohibited.
History
(Ord. No. 98-08, § 9, 6-23-1998; Ord. of 10-19-2010(2), § 2)