Block lengths shall not be less than 400 feet and where residential subdivisions are to be built, blocks shall not exceed 1,200 feet. Intersections with collector or arterial roads shall not be located closer than 400 feet of the crest of a hill. Each proposed road intersection shall be, if at all possible, at right angles but in no case shall any intersection angle be less than 75 degrees. If the basic alignment of a proposed road has to be deflected to achieve the required intersection angle, the sight distance from the centerline of the road in the curve to the intersection shall be at least 400 feet for a collector road, and 150 feet for a minor residential road. No proposed intersection shall be offset less than 200 feet, whether the intersection is on a proposed road or between a proposed road and an existing road where the proposed new road is, in effect, a continuation of an existing road.
History
(Ord. of 4-12-1982, § 302)