--- title: Stephens County Code of Ordinances, Sec. 34-109. Ten percent downstream analysis collection: local-codes id: local-code:stephens-county/code/34-109 cite_as: Stephens County, Ga., Code of Ordinances § 34-109 canonical_url: https://georgiacommons.org/counties/stephens/code/34-109 md_url: https://georgiacommons.org/counties/stephens/code/34-109.md text_url: https://georgiacommons.org/counties/stephens/code/34-109/text source_url: https://library.municode.com/ga/stephens_county/codes/code_of_ordinances date: 2026-09-08 status: active jurisdiction: county:stephens jurisdiction_name: Stephens County county_fips: "13257" corpus_version: local-codes-stephens-county-788b55145d06 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/stephens/code/~part-code-of-ordinances/~chapter-34/~article-iv/~division-2.md previous: https://georgiacommons.org/counties/stephens/code/34-106.md next: https://georgiacommons.org/counties/stephens/code/34-110.md index: https://georgiacommons.org/counties/stephens.md branch: code edition: As published by Municode, current through 2026-09-08 edition_date_kind: current_through source_publisher: Municode version_id: local-code:stephens-county/code/34-109@2026-09-08-d634c5dc2d --- # Stephens County Code of Ordinances, Sec. 34-109. Ten percent downstream analysis > As published by Municode, current through 2026-09-08 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part - CODE OF ORDINANCES / Chapter 34 - ENVIRONMENT / Article IV - STORMWATER MANAGEMENT / Division 2 - STORMWATER MANAGEMENT REQUIREMENTS Analysis of downstream conditions shall, at a minimum, include the following: Ten percent downstream analysis (from all ponds and site in general); • Ten percent downstream analysis (where site area, is less than ten percent of the drainage basin area); • Identification of all affected structures between lower limit of site and ten percent analysis point; • Analysis of all affected structures between lower limit of site and ten percent analysis point; • Prerouting and postrouting analysis; • Describe in combination with a topographic map, all culverts, obstructions, existing and potential erosion problems, elevations of existing improvements, and existing drainage complaints, between the downstream property line and the ten percent point; • Analyze downstream watercourses and receiving conveyances to determine 25-year flow channel velocities. If the nonerosive velocity of the stream is exceeded, detention may be required. Provide calculations with cross-section, depth of flow and velocity in channel; • Analyze existing pipe systems and culverts for compliance with current development regulation design criteria. Culverts should pass QIOO. If existing pipes are not adequate for increased 100-year flow, detention may be required. (DR 8.2.Ic); • Hydrograph comparisons for the one-, two-, five-, ten- 25- 50- and 100-year storms for both the downstream property line study point and the point where the drainage basin equals ten times the project area; • A detailed written description of the first 500 feet off site; at least one photograph looking downstream with some object included in the photograph for scale shall be included; • Predeveloped on-site hydrograph; • Basin area at study point excluding on-site area hydrograph; • Postdeveloped on-site hydrograph; • Since downstream analysis indicates adverse impacts are expected, provide stormwater detention in basin(s) for the one-, two-, five-, ten-, 25-, 50- and 100-year storm event. Route the 100-year storm through the pond so that there is no overflow from the pond; • Detain the runoff from the one-year storm for 24 hours. Use the SCS runoff equation to size the volume required. Use appropriate equations to size the orifice • Schedule a meeting to discuss any county comment(s); • All hydrographs shall be based on a 24-hour storm. • Orifices less than three inches in diameter must be protected from clogging. A trash rack (maximum mesh opening of d/2) with a surface area of at least 10 square feet shall protect all orifices 15" or less in diameter. Provide detail. Racks should be easily cleaned and maintained. ## History (Ord. No. 2010-34-2, 10-12-2010)