(a) (1) Determination of need. No new nonconcealed PWSF shall be permitted unless the applicant demonstrates that no existing tower can accommodate the applicant's proposed use; or that use of such existing facilities would prohibit personal wireless services in the geographic search area to be served by the proposed tower. (2) Height. Height calculations shall include above ground foundations, but exclude lightning rods or lights required by the FAA that do not provide any support for antennas. It is intended that all new non-broadcasting non-concealed PWSF towers be 120 feet or less in height. However, should a non-concealed PWSF tower applicant for a site located in a non-residential zoning district adequately demonstrate that a height in excess of 120 feet is required to provide service, under no circumstance shall any nonconcealed PWSF tower in a non-residential zoning district exceed 199 feet. (3) Setbacks. New non-concealed PWSFs and equipment compounds shall be subject to the setbacks described below for breakpoint technology: a. If the non-concealed PWSF tower is constructed using breakpoint design technology (see �definitions�), the minimum setback distance shall be equal to 110 percent of the distance from the top of the structure to the breakpoint level of the structure, or the minimum side and rear yard requirements, whichever is greater. Certification by a registered professional engineer licensed by the State of Georgia of the breakpoint design and the design's fall radius must be provided together with the other information required herein from an applicant. (For example, on a 100-foot-tall monopole with a breakpoint at 80 feet, the minimum setback distance would be 22 feet (110 percent of 20 feet, the distance from the top of the monopole to the breakpoint) plus the minimum side or rear yard setback requirements for that zoning district). b. If the non-concealed PWSF tower is not constructed using breakpoint design technology, the minimum setback distance shall be equal to the height of the proposed PWSF. (4) Equipment cabinets and equipment shelters. Electronic equipment shall be contained in either (a) equipment cabinets or (b) equipment shelters. Equipment cabinets shall not be visible from pedestrian and right-of-way views. Equipment cabinets may be provided within the principal building, behind a screen on a rooftop, or on the ground within the fenced-in and screened equipment compound. (5) Fencing. All equipment compounds shall be enclosed with an opaque fence or masonry wall in residential zoning districts, and in any zoning district when the equipment compound adjoins a public right-ofPERSONAL WIRELESS SERVICE FACILITY (PWSF) § 75-66 way. Alternative equivalent screening may be approved through the site plan approval process. (6) Buffer. The equipment compound shall be landscaped with a minimum ten-footwide perimeter buffer containing the following planting standards: a. All plants and trees shall be indigenous to this part of Georgia. b. Existing trees and shrubs on the site should be preserved and may be used in lieu of required landscaping as approved by the planning department. c. One row of evergreen trees with a minimum two-inch caliper, 25-foot on center. d. Evergreen shrubs capable of creating a continuous hedge and obtaining a height of at least five feet shall be planted, minimum three-gallon or 24 inches tall at the time of planting, five-foot on center. e. Alternative landscaping plans which provide for the same average canopy and understory trees but propose alternative locating on the entire subject property may be considered and approved by the planning department, provided the proposed alternative maximizes screening as provided above, and is otherwise consistent with the requirements of this section. (7) Signage. Commercial messages shall not be displayed on any non-concealed PWSF tower. Required noncommercial signage shall be subject to the following: a. The only signage that is permitted upon a non-concealed PWSF tower, equipment cabinets, shelters or fence shall be informational, and for the purpose of identifying the PWSF (such as ASR registration number), as well as the party responsible for the operation and maintenance of the facility, and any additional security and/or safety signs as applicable. b. If more than 220 voltage is necessary for the operation of the facility and is present in a ground grid or in the tower, signs located every 20 feet and attached to the fence or wall shall display in large, bold, high contrast letters, minimum height of each letter four inches, the following: "HIGH VOLTAGE - DANGER." c. Name plate signage shall be provided, in an easily visible location, including the address and telephone number of the contact to reach in the event of an emergency or equipment malfunction, including property manager signs as applicable. (8) Lighting. Lighting on non-concealed PWSF towers shall not exceed the Federal Aviation Administration (FAA) minimum standards. All other lighting shall be subject to the following: a. Any lighting required by the FAA must be of the minimum intensity and number of flashes per minute (i.e., the longest duration between flashes) allowable by the FAA. Dual lighting standards are required with strobe during daytime and red flashing lights at night unless prohibited by the FAA. b. Lights shall be filtered or oriented so as not to project directly onto surrounding property or rights-of-way consistent with FAA requirements. (9) Equipment compound. The fenced-in compounds shall not be used for the storage of any excess equipment or hazardous materials. No outdoor storage yards shall be allowed in a tower equipment compound. The compound shall not be used as habitable space. (10) Visibility. a. New non-concealed PWSF towers shall be configured and located in a manner that shall minimize adverse effects including visual impacts on the landscape and adjacent properties. b. A balloon test shall be required subsequent to the receipt of the photo simulations in order to demonstrate the proposed height of the tower. The applicant shall arrange to raise a colored balloon no less than three feet in diameter at the maximum height of the proposed tower, and within 25 horizontal feet of the center of the proposed tower. c. A three-foot by five-foot sign with lettering no less than three inches high stating the purpose of the balloon test shall be [placed] at [the] closest major intersection of proposed site. d. The applicant shall meet the following for the required balloon test: 1. Applicant must inform the planning department and abutting property owners in writing of the date and times, including alternative date and times, of the test at least 14 days in advance. 2. The date, time, and location, including alternative date, time and location, of the balloon test shall be advertised in a locally distributed paper by the applicant at least seven but no more than 14 days in advance of the test date. 3. The balloon shall be flown for at least four consecutive hours during daylight hours on the date chosen. The applicant shall record the weather during the balloon test. 4. Readvertisement will not be required if inclement weather occurs. e. New antenna mounts shall be flushmounted, unless it is demonstrated through RF propagation analysis that flush-mounted antennas will not meet the network objectives of the desired coverage area. f. Non-concealed PWSF towers shall be constructed to accommodate antenna arrays as follows: 1. All freestanding towers up to 120 feet in height shall be engineered and constructed to accommodate no less than four antenna arrays. 2. All towers between 121 feet and 150 feet shall be engineered and constructed to accommodate no less than five antenna arrays. g. Grading shall be minimized and limited only to the area necessary for the new PWSF and equipment compound. h. Freestanding non-concealed PWSF towers shall be limited to monopole type towers, unless the applicant demonstrates that such design is not feasible to accommodate the intended uses. (b) Application requirements. (1) Completion of PWSF application. (2) Application fee. (3) Applicant shall provide a written statement of compliance with all applicable FCC rules and regulations. (4) Applicant shall provide a complete set of construction drawings of the proposed facility demonstrating compliance with applicable federal, state and Stephens County building codes. (5) A map of the same search ring submitted and used by the applicant's site locator with a statement confirming the same. (6) A map indicating applicant's existing RF signal propagation, a map indicating applications proposed new RF signal propagation, and a map indicating the proposed improvements' coverage area, which provides sufficient justification for the requested support structure. (7) A statement from the applicant providing information regarding justification for the proposed new non-concealed PWSF facility. A report and supporting technical data shall be submitted, demonstrating the following: a. Location of all potential alternative structures including utility distribution towers and other elevated structures within the proposed service area have been examined, and found unacceptable. b. Reasoning as to why alternative structures are not acceptable. (8) Proof that a property and/or tower owner's agent has appropriate authorization to act upon the owner's behalf (if applicable). (9) An affidavit by a radio frequency engineer demonstrating compliance with "locating alternatives order" section of this chapter. If a lower ranking alternative is proposed the affidavit must address why higher ranked options are not technically feasible, practical, and/or justified given the location of the proposed communications facility. (10) Statement as to the potential visual and aesthetic impacts of the proposed tower and equipment on all adjacent residential zoning districts. (11) Written statement by a registered professional engineer licensed by the State of Georgia specifying the design structural failure modes of the proposed facility, if applicable. (12) Statement certifying that no unusual sound emissions such as alarms, bells, buzzers, or the like are permitted. Emergency generators are permitted. Sound levels shall not exceed 65 dB as measured at the closest property boundaries for the facility. (13) A radio frequency propagation plot indicating the coverage of existing antenna sites, coverage prediction, and design radius, together with a certification from the applicant's radio frequency (RF) engineer that the proposed facility's coverage or capacity potential cannot be achieved by any higher ranked alternative such as a concealed facility, attached facility, replacement facility, collocation, or new tower, and the reasoning why such alternatives are unacceptable. A radio frequency propagation plot indicating the proposed improvements' coverage area, which provides sufficient justification for the requested support structure height. (14) One original and two copies of a survey of the property completed by a registered professional engineer, licensed in the State of Georgia showing all existing uses, structures, and improvements. (15) Six sets (24″×36″) of signed and sealed site plans shall include the following: a. Name of project and date. b. Deed book, and page and map book and page reference. c. Scale, north arrow, and vicinity map. d. Subject property information including zoning, watershed classification, percent coverage of lot to be impervious surface (if located in a designated watershed area). e. Adjacent property information, including landowners, land uses, height of principal building, size of lots, zoning, and land use designation. f. Tower elevations. g. Landscape buffering plans. h. Maximum height of the proposed tower and proposed and future mounting elevations of future anPERSONAL WIRELESS SERVICE FACILITY (PWSF) § 75-66 tenna, including individual measurement of the base, the tower, and lightning rod. i. Location, classification, and size of all major public or private streets and rights-of-way. j. Identify adjacent features within 500 feet of property boundary including driveways, public parking areas, pedestrian ways, trails, and any other pertinent features. k. Two reduced copies (81 /2″×11″), of the foregoing preliminary grading plans may be included on site plans or separately submitted in equal quantities. (16) Title report or American Land Title Association (A.L.T.A.) survey showing all easements on the subject property, together with a full legal description of the property. (17) List of adjacent property owners and keyed to the map. The list must be from the most current ownership information supplied by the county tax department, together with two sets of mailing labels for such property owners. Applicant will also provide a notarized certification letter stating the ownership list referenced herein is accurate to the best of the applicant's ability. (18) Simulated photographic evidence of the proposed tower and antenna appearance from any and all residential areas within 1,500 feet and vantage points approved by the planning department including the facility types the applicant has considered and the impact on adjacent properties including: a. Overall height. b. Configuration. c. Physical location. d. Mass and scale. e. Materials and color. f. Illumination. g. Architectural design. (19) All other documentation, evidence, or materials necessary to demonstrate compliance with the applicable approval criteria set forth in this chapter. (20) Prior to issuance of a building permit, proof of FAA compliance with Subpart C of the Federal Aviation Regulations, Part 77, and "Objects Affecting Navigable Airspace," if applicable. (21) Proof of compliance with National Environmental Policy Act and National Historic Preservation Act.