--- title: Talbot County Code of Ordinances, Sec. 18-151. Site plans collection: local-codes id: local-code:talbot-county/code/18-151 cite_as: Talbot County, Ga., Code of Ordinances § 18-151 canonical_url: https://georgiacommons.org/counties/talbot/code/18-151 md_url: https://georgiacommons.org/counties/talbot/code/18-151.md text_url: https://georgiacommons.org/counties/talbot/code/18-151/text source_url: https://library.municode.com/ga/talbot_county/codes/code_of_ordinances date: 2019-11-04 status: active jurisdiction: county:talbot jurisdiction_name: Talbot County county_fips: "13263" corpus_version: local-codes-talbot-county-37d516d43d74 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/talbot/code/~part-ii/~chapter-18/~article-iv/~division-3.md previous: https://georgiacommons.org/counties/talbot/code/18-124-to-18-150.md next: https://georgiacommons.org/counties/talbot/code/18-152.md index: https://georgiacommons.org/counties/talbot.md branch: code edition: As published by Municode, current through 2019-11-04 edition_date_kind: current_through source_publisher: Municode version_id: local-code:talbot-county/code/18-151@2019-11-04-31553c1af9 --- # Talbot County Code of Ordinances, Sec. 18-151. Site plans > As published by Municode, current through 2019-11-04 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 18 - ENVIRONMENT / Article IV - FLINT RIVER PROTECTION / Division 3 - ADMINISTRATION AND ENFORCEMENT Application for a local development permit within the Flint River corridor protection district shall include a site plan, drawn at a scale of one inch equals 50 feet, with the following information: (1) A map of all planned excavation and fill, including calculations of the volume of cut and fill involved and cross-sectional drawings showing existing and proposed grades. Elevations, horizontal scale and vertical scale must be shown on the cross-sectional drawings. (2) Location, dimensions and area of all impervious surfaces, both existing and proposed, on the site and adjacent to the site for a distance of 200 feet. (3) The orientation and distance from the boundaries of the proposed site to the nearest bank of an affected perennial stream or water body. (4) Elevations of the site and adjacent lands within 200 feet of the site at contour intervals of no greater than two feet; and no greater than one foot for slopes less than or equal to two percent. (5) Location and detailed design of any spill and leak collection systems designed for the purpose of containing accidentally released hazardous or toxic materials. (6) All proposed temporary disruptions or diversions of local hydrology. ## History (Ord. of 9-10-2001(1), § 6A)