--- title: Talbot County Code of Ordinances, Sec. 42-172. Protection criteria collection: local-codes id: local-code:talbot-county/code/42-172 cite_as: Talbot County, Ga., Code of Ordinances § 42-172 canonical_url: https://georgiacommons.org/counties/talbot/code/42-172 md_url: https://georgiacommons.org/counties/talbot/code/42-172.md text_url: https://georgiacommons.org/counties/talbot/code/42-172/text source_url: https://library.municode.com/ga/talbot_county/codes/code_of_ordinances date: 2019-11-04 status: active jurisdiction: county:talbot jurisdiction_name: Talbot County county_fips: "13263" corpus_version: local-codes-talbot-county-37d516d43d74 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/talbot/code/~part-ii/~chapter-42/~article-iv/~division-2.md previous: https://georgiacommons.org/counties/talbot/code/42-171.md next: https://georgiacommons.org/counties/talbot/code/42-173.md index: https://georgiacommons.org/counties/talbot.md branch: code edition: As published by Municode, current through 2019-11-04 edition_date_kind: current_through source_publisher: Municode version_id: local-code:talbot-county/code/42-172@2019-11-04-c77ae0030d --- # Talbot County Code of Ordinances, Sec. 42-172. Protection criteria > As published by Municode, current through 2019-11-04 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 42 - WATER AND SEWER / Article IV - WATER SUPPLY WATERSHED PROTECTION / Division 2 - WATER SUPPLY WATERSHED DISTRICT (a) Lazer Creek water supply watershed. The following regulations shall apply to the Lazer Creek water supply watershed identified on the adopted map as a small water supply watershed. (1) The corridors of all perennial streams within a seven-mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria: a. A buffer shall be maintained for a distance of 100 feet on both sides of the stream as measured from the stream banks. b. No impervious surface shall be constructed within a 150-foot setback area on both sides of the stream as measured from the stream bank. c. Septic tanks and septic tank drainfields are prohibited in the 150-foot setback area as described in subsection (a)(1)b above. (2) The corridors of all perennial streams outside a seven-mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria: a. A buffer shall be maintained for a distance of 50 feet on both sides of the stream as measured from the stream banks. b. No impervious surface shall be constructed within a 75-foot setback area on both sides of the stream as measured from the stream bank. c. Septic tanks and septic tank drainfields are prohibited in the 75-foot setback area as described in subsection (a)(2)b above. (3) The impervious surface area, including all public and private structures, utilities, or facilities, of the entire water supply watershed shall be limited to 25 percent, or existing use, whichever is greater. (b) Rush Creek reservoir water supply watershed. The following regulations shall apply to the Rush Creek reservoir water supply watershed identified on the adopted map as a small water supply watershed with a reservoir known as the Rush Creek reservoir. (1) The corridors of all perennial streams within a seven-mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria: a. A buffer shall be maintained for a distance of 100 feet on both sides of the stream as measured from the stream banks. b. No impervious surface shall be constructed within a 150-foot setback area on both sides of the stream as measured from the stream bank. c. Septic tanks and septic tank drainfields are prohibited in the 150-foot setback area as described in subsection (b)(1)b above. (2) The corridors of all perennial streams outside a seven-mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria: a. A buffer shall be maintained for a distance of 50 feet on both sides of the stream as measured from the stream banks. b. No impervious surface shall be constructed within a 75-foot setback area on both sides of the stream as measured from the stream bank. c. Septic tanks and septic tank drainfields are prohibited in the 75-foot setback area as described in subsection (b)(2)b above. (3) The impervious surface area, including all public and private structures, utilities, or facilities, of the entire water supply watershed shall be limited to 25 percent, or existing use, whichever is greater. (4) A buffer shall be maintained for a distance of 150 feet from the reservoir boundary. The allowable buffer vegetation and disturbance is specified in the reservoir management plan. (5) The Rush Creek reservoir is owned by the City of Manchester and will be protected as described in the Rush Creek reservoir management plan. ## History (Ord. of 11-5-2001, § 4)