(a) For minor subdivisions: All roads must be brought up to an elevation at least 12 inches above the 100 year flood plain, be equipped with proper drainage pipes, including driveway and ramp pipes, and have drainage easements and out-fall ditches as needed. All cross drains shall contain a minimum of 32 feet of approved pipe of a size sufficient to provide for proper drainage. All drainage pipes must be concrete or double wall ADS. The county engineer must approve road elevations, drainage plan, drainage structures, cross drains and out-fall ditches before installation. (b) For major subdivisions: All roads and lots must be brought up to an elevation at least 12 inches above the 100 year flood plain. All roads must be equipped with proper drainage structures, including storm drains. Drainage easements, retention ponds, and outfall ditches should be in place if necessary. The county engineer must approve road elevations, drainage plan, and drainage structures before installation.