On or after July 1, 1991, no construction may be initiated within the county for any residential building of any type which: (1) Employs a gravity tank-type, flushometer-valve, or flushometer-tank toilet that uses more than an average of 1.6 gallons of water per flush; provided, however, that this subsection shall not be applicable to one-piece toilets until July 1, 1992. (2) Employs a showerhead that allows a flow of more than average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure. (3) Employs a urinal that uses more than an average of one gallon of water per flush. (4) Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than two gallons of water per minute. (5) Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than 2.5 gallons of water per minute.