(a) Soil Information Required: No parcel of land will be approved for an on-site sewage management system without soil information presented in the manner prescribed by the Manual for On-Site Sewage Management Systems. Soil Information must be provided for the entire lot, or one acre, whichever is less.
(b) Properties served by a community sewage system, not exceeding 10,000 gallons per day usage, shall meet the minimum lot size requirements. The combination of the individual properties and the area for the on-site sewage management system must average to meet the requirements needed for the total number of lots and gallon per day usage.
(c) Lot size requirement: To provide for the orderly and safe development of property utilizing on-site sewage management systems, minimum lot sizes are established as follows:
(1) Minimum Lot Sizes: Lot size requirements are as follows for single family dwellings and other structures including but not limited to: manufactured or mobile homes, stick built homes, modular homes, etc. and individual lots in subdivisions, mobile home parks, and commercial developments. Aera requirements for multiple dwellings or structures on a single recorded lot, where not prohibited under local law, must be provided in multiples of the following minimum lot sizes for each dwelling or structure to be constructed on the recorded lot. Also, lot-sizing requirements are as follows for multi-family residential dwellings, all other non-single family dwellings and commercial structures. The minimum non-restricted area for a lot to be accepted is noted in Table 1 below. Subparagraphs a. through d. below, also apply for lot sizes.
Larger lot sizes may be required to meet the requirements of the manual depending on the proposed development of the property. County Zoning Authorities may require larger minimum lot sizes; such establishments of larger minimum lot sizes will take precedence.
TABLE 1
WATER SUPPLY NON-PUBLIC*
INDIVIDUAL
PUBLIC
Minimum Lot Size 65,340 square feet
1.5 acre 32,670 square feet
0.75 acre Maximum Sewage Flow for Minimum Lot Size 900 gpd (Based on 600 gad**) 900 gpd (Based on 1200 gad) Formula for Greater Sewage Flows Sewage Flow: Lot Size X/600=acres X/1200=acres *In this context, "Non-public" means an individual water supply system or any other water supply system, which is not a "public" water supply system.
**gallons per acre per day X = gallons per day
a. The above minimum lot sizes are for the typical three or four bedroom home with basic appurtenances such as: driveway, minimum number of trees, and water supply line. If commercial structures with higher gallons per day flows, larger homes, swimming pools, tennis courts or outbuilding, etc., are proposed to be constructed or if trees would interfere with installation of an on-site sewage management system, the County Board of Health or its designee will require larger lots to assure useable soil area.
b. The County Board of Health or its designee may also require larger lot sizes when physical factors indicate the need to do so. These factors include, but are not limited to the availability of sufficient unobstructed land areas for an approved on-site sewage management system and approved replacement system, need for subsurface drainage or adverse topographic features, and the soil available must be approved for use according to the Georgia Department of Community Health, Public Health Section, Rules for On-site Sewage Management Systems.
c. There must be an unobstructed area on each lot for the installation of an approved on-site sewage management system and for an approved replacement system area equal to a conventional system or larger area, as appropriate. This will include sufficient area for necessary site modifications for installation of both the initial system and a replacement system. All pertinent County zoning setbacks and other space requirements must also be met.
d. The maximum daily sewage flow for each lot or parcel of land shall not exceed 600 gpad when served by a non-public or individual water supply system or 1200 gpad when served by a public water supply system. When sewage flows exceed these quantities for a given dwelling or structure, the minimum lot size or parcel of land shall be increased proportionately.
(d) An on-site sewage management system permit may be issued provided that it follows all state and local laws, rules, and resolutions.