(a) Every existing building shall be accessible to Fire Department apparatus by way of access roadways with all-weather driving surfaces of not less than 20 feet (6.1 m) of unobstructed clear width, with adequate roadway turning radius capable to supporting the imposed loads of the fire apparatus and having a minimum vertical clearance of 13 feet 6 inches (4.1 m).

(1) Where fire protection systems approved by the Fire Official are provided, the above-required clearances may be modified by the Fire Official.

(2) The Fire Official shall have the authority to require an increase in the minimum access widths where they are inadequate for fire or rescue operations.

(b) Every new building shall be accessible to Fire Department apparatus by way of designated fire lanes with an all-weather surface of not less than 20 feet (6.1 m) of unobstructed clear width. There shall be a minimum roadway turning radius of 35 feet (10.6 m). There shall be a minimum vertical clearance of 13 feet 6 inches (4.1 m).

The designated fire lanes shall be paved, poured concrete, or equivalent, capable of supporting the gross vehicle weight of fire apparatus.

(1) Where fire protection systems approved by the Fire Official are provided, the above-required clearances may be modified by the Fire Official.

(2) The Fire Official shall have the authority to require an increase in the minimum access widths where they are inadequate for fire or rescue operations.

(c) During construction, when combustibles are brought onto the site in such quantities as deemed hazardous by the Fire Official, access roads and a suitable water supply, acceptable to meet the required needed fire flow, shall be provided and maintained.

(d) The areas designated as fire lanes shall have signs posted meeting the following criteria:

(1) Signs shall read "No Parking Fire Lane," be constructed of a material to withstand the elements, such as metal, and lettering shall contrast against the background.

(2) Letters shall not be less than 2 inches in height.

(3) One sign shall be placed at the beginning of the fire lane and 1 at the end of the fire lane and a sign shall be erected every 50 feet of the fire lane.

(4) Signs posted shall not be more than 4 feet from the edge of the curb and shall be visible from both driving directions, regardless of time of day or the driving surfaces.

(e) Painted lines, or equivalent, may be required by the Fire Official for that portion of the fire lane that is located in the parking areas, or is subject to blocking by parked vehicles. Such lines shall be yellow and clearly define an area 20 feet clear width from the building as no parking fire lane.

(f) The Fire Official may require curbs of non-parking areas be painted red or other distinctive colors.

History

The history line the source prints at the end of the section.

(Ord. of 11-16-2006, § 23-5.3)