(a) General standards. In all areas of special flood hazard, the following provisions are required: (1) New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure; (2) Manufactured homes shall be anchored to prevent flotation, collapse or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable State requirements for resisting wind forces; (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; (4) New construction and substantial improvements shall be constructed by methods and practices that minimize flood damage; (5) Electrical heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located to prevent water from entering or accumulating within the components during conditions of flooding; (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters; (8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding; (9) Any alteration, repair, reconstruction or improvement to a structure which is in compliance with the provisions of this section shall meet the requirements of new construction as contained in this section; and (10) Any alteration, repair, reconstruction or improvement to a building, which is not in compliance with the provisions of this section, shall be undertaken only if said non-conformity is not furthered, extended or replaced. (b) Specific standards. In all areas of special flood hazard where base flood elevation data has been provided, the following provisions are required: (1) Residential construction. New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated no lower than 1 foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards set forth in this section. (2) Non-residential construction. New construction or substantial improvement of any commercial, industrial or non-residential structure shall have the lowest floor, including basement, elevated no lower than 1 foot above the level of the base flood elevation. Structures located in all A zones may be floodproofed in lieu of being elevated, provided that all areas of the structure below the required elevation are watertight, with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. (3) Elevated buildings. a. New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. b. Designs for complying with this requirement must either be certified by a professional engineer or architect, or meet the following minimum criteria: 1. Provide a minimum of 2 openings having a total net area of not less than 1 square inch for every foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than 1 foot above grade; and 3. Openings may be equipped with screens, louvers, valves or other coverings or devices, provided they permit the automatic flow of floodwaters in both directions. c. Electrical, plumbing and other utility connections are prohibited below the base flood elevation. d. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator). e. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) Floodways. Located within areas of special flood hazard are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris and potential projectiles and has erosion potential, the following provisions shall apply: a. Encroachments shall be prohibited, including fill, new construction, substantial improvements and other land-disturbing activity, unless certification (with supporting technical data) by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. b. If the requirement of subsection (b)(4)a of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section. c. The placement of manufactured homes (mobile homes) shall be prohibited, except in an existing manufactured home (mobile home) park or subdivision. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision, provided the anchoring standards and elevation standards of this section are met. (5) Manufactured home and recreational vehicle standards. a. All manufactured homes placed or substantially improved on individual lots or parcels, in expansions to existing manufactured home parks or subdivisions or in substantially improved manufactured home parks or subdivisions, must meet all the requirements for new construction, including elevation and anchoring. b. All manufactured homes placed or substantially improved in an existing manufactured home park or subdivision must be elevated so that: 1. The lowest floor of the manufactured home is elevated no lower than 1 foot above the level of the base flood elevation. 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above grade. 3. The manufactured home must be securely anchored to the adequately anchored foundation system to resist flotation, collapse and lateral movement. c. In an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as the result of a flood, any manufactured home placed or substantially improved must meet the standards of subsections (b)(5)b.1 and 3 of this section. d. All recreational vehicles placed on sites must either: 1. Be fully licensed and ready for highway use. 2. Meet all the requirements for new construction, including anchoring and elevation requirements of subsection (b)(5)a or (b)(5)b.1 and 3 of this section. e. A recreational vehicle is ready for highway use if it: 1. Is on its wheels or jacking system; 2. Is attached to the site only by quick disconnect type utilities and security devices; and 3. Has no permanently attached structures. (c) Standards for streams without established base flood elevations and/or floodways. Located within the areas of special flood hazard established in subsection (b) of this section, where small streams exist but where no base flood data has been provided or where no floodways have been provided, the following provisions apply: (1) No encroachments, including fill material or structures, shall be located within a distance of the stream bank equal to 3 times the width of the stream at the top of the bank or 20 feet each side from the top of the bank, whichever is greater, unless certification by a registered professional engineer is provided demonstrating that such encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. (2) New construction or substantial improvements of structures shall be elevated or floodproofed to elevations established in accordance with this section. (d) Subdivision proposal standards. (1) All subdivision proposals shall be consistent with the need to minimize flood damage; (2) All subdivision proposals shall have public utilities and facilities, such as sewer, gas, electrical and water systems, located and constructed to minimize flood damage; (3) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and (4) Base flood elevation data shall be provided for subdivision proposals and other proposed development (including manufactured home parks and subdivisions) which are greater than the lesser of 50 lots or 5 acres. (e) Standards for areas of shallow flooding (AO zones). Located within the areas of special flood hazard established in subsection (b) of this section are areas designated as shallow flooding areas. These areas have special flood hazards associated with base flood depths of 1 to 3 feet, where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no depth number is specified, the lowest floor, including basement, shall be elevated at least 2 feet above the highest adjacent grade. (2) All new construction and substantial improvements of non-residential structures shall: a. Have the lowest floor, including basement, elevated to the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no depth number is specified, the lowest floor, including basement, shall be elevated at least 2 feet above the highest adjacent grade; or b. Together with attendant utility and sanitary facilities, be completely floodproofed to or above that level so that any space below that level is watertight, with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.