Sec. 22-406. Required improvements.
About this text
- As published by Municode, current through 2026-07-09
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The subdivider is required to install or construct the following improvements prior to having released the bond or other securities which guarantee installation of such required improvements. All improvements required shall be constructed in accordance with the standards set forth in these regulations, and under the inspection of the County Road Superintendent or his duly authorized representative and the Engineering Department of the respective utility. All water mains, sanitary sewers and laterals, and storm sewers shall be installed as necessary to prevent the future cutting of the pavement of any street, sidewalk or other required pavement.
(1) Streets and alleys. On all streets and alleys within the jurisdiction of these regulations, a suitable hard surfaced, permanent type of pavement shall be constructed in accordance with the County construction specifications adopted by the County Board of Commissioners.
(2) Sidewalks. Sidewalks shall be placed on both sides of all streets in a commercial subdivision; sidewalks shall be required on at least 1 side of all streets in residential subdivisions. Sidewalks shall be a minimum of 4 feet wide in residential areas and 7 feet wide in business areas, and shall be constructed according to County specifications, including Federal ADA requirements.
(3) Curbs and gutters. Standard approved type curbs and gutters must be placed on both sides of all new streets within the area of jurisdiction of these regulations in accordance with the specifications of the County.
(4) Water system.
a. Where a public water supply is within 300 feet of any property line, the party seeking a building permit for a residence shall connect with the same at his own expense. Where a public water supply is within the following distances of any subdivision, the subdivider at his own expense shall connect with the same: 300 feet for 1 dwelling unit, plus 50 feet for each additional dwelling unit possible within the approved plat design. These distance standards will be enforced if the utility supplier commits to install, in a timely fashion, lines to a location within the distance as would require the developer to connect in the particular circumstance. The design and specifications of the distribution system shall meet the State water supply requirements. Water mains shall be extended the full length or width of the pavement.
b. If a well is required for each lot, the location, construction and use of such a well shall also meet State Department of Human Resources requirements. Subdivision plats designed for each lot to use individual wells will only be considered for minor subdivisions. If a well is to serve more than 1 lot, a public water system shall be required. The design and specifications of such distribution system shall meet Health Department specifications, and shall be installed under inspection of the Health Department.
(5) Fire plugs. Fire plugs, which meet design and specification standards as adopted by the Walker County Fire Department (WCFD), with each plan individually approved by the WCFD, shall be installed along each street at a maximum interval of 900 feet, or at the ends and center of each block. The water supply and pressure shall be sufficient to adequately serve the potential needs of the intended land use.
(6) Sanitary sewers.
a. Where a public sanitary sewer system is within 300 feet of any property line, the party seeking a building permit for a residence shall connect with the same at his own expense. Where a public sanitary sewer system is within the following distances of any subdivision, the subdivider or developer at his own expense shall connect with the same: 300 feet for 1 dwelling unit, plus 50 feet for each additional dwelling unit possible within the approved plat design. These distance standards will be enforced if the utility supplier commits to install, in a timely fashion, lines to a location within the distance as would require the developer to connect in the particular circumstance. The design and specifications of the distribution system shall meet the State water supply requirements.
Water mains shall be extended the full length or width of the pavement.
b. If a private system is installed, it shall be constructed in accordance with the requirements of a public system. If septic tanks are installed, special approval must be obtained from the Health Department. Lot size shall not be less than the minimum standard, and shall be of satisfactory size for the proper installation of a septic tank sewage system as indicated by percolation tests.
(7) Storm sewers and drainage structures. Storm sewers and drainage structures shall be designed and installed as required in accordance with good engineering practice. In no case shall the size of pipe used for storm drainage be less than 15 inches in diameter. The subdivider shall provide either:
a. Portland cement concrete or asphaltic concrete curb, the face of which shall not be less than 6 inches in height, with backfill sloping toward the curb and higher than the curb to ensure drainage of surface water into the storm drainage system; or
b. Properly constructed drainage ditches, with the valley line of the ditch at least 6 feet from the edge of the roadway surface. Where possible, the slopes of the ditch should be in a ratio of at least 3:1, but in no case shall they exceed a ratio of 2:1. Where the grade of the roadway exceeds 5 percent, the Planning Commission may require the developer to rip rap the ditches.
(8) Property markers. All lot corners shall be marked with iron pipe not less than 3 /4 inch in diameter and 24
inches long, and driven so as to be flush with the finished grade.
(9) Street signs. One street sign will be required for each intersection.
(10) Placement of utilities. The developer is encouraged to place all utilities underground. The street right-of-way shall be graded at least 6 feet, measured from the back of the curb or edge of the pavement on both sides of the street, to provide space for the installation of utilities, to prevent the encroachment of driveways into the street surface, to provide walkways off the paved vehicular surface, and to provide space for the future installation of sidewalks; provided, however, the Planning Commission may waive this requirement in cases where the subdivider can demonstrate that the topography of the land being subdivided is such that compliance with this provision would be impractical.
History
(Code 2005, § 34-493; Ord. of 7-20-1994, § 9.23; Ord. of 3-16-2006)