--- title: Walker County Code of Ordinances, Sec. 22-753. Water quality collection: local-codes id: local-code:walker-county/code/22-753 cite_as: Walker County, Ga., Code of Ordinances § 22-753 canonical_url: https://georgiacommons.org/counties/walker/code/22-753 md_url: https://georgiacommons.org/counties/walker/code/22-753.md text_url: https://georgiacommons.org/counties/walker/code/22-753/text source_url: https://library.municode.com/ga/walker_county/codes/code_of_ordinances date: 2026-07-09 status: active jurisdiction: county:walker jurisdiction_name: Walker County county_fips: "13295" corpus_version: local-codes-walker-county-34d5670eb847 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/walker/code/~part-ii/~chapter-22/~article-viii/~division-3.md previous: https://georgiacommons.org/counties/walker/code/22-752.md next: https://georgiacommons.org/counties/walker/code/22-754.md index: https://georgiacommons.org/counties/walker.md branch: code edition: As published by Municode, current through 2026-07-09 edition_date_kind: current_through source_publisher: Municode version_id: local-code:walker-county/code/22-753@2026-07-09-7334543183 --- # Walker County Code of Ordinances, Sec. 22-753. Water quality > As published by Municode, current through 2026-07-09 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 22 - LAND DEVELOPMENT / Article VIII - POST-DEVELOPMENT STORMWATER MANAGEMENT FOR NEW DEVELOPMENT AND REDEVELOPMENT / Division 3 - POST-DEVELOPMENT STORMWATER MANAGEMENT PERFORMANCE CRITERIA All stormwater runoff generated from a site shall be adequately treated before discharge. Stormwater management systems, which can include both structural stormwater controls and better site design practices, must be designed to remove 80 percent of the average annual post-development total suspended solids (TSS) load and be able to meet any other additional watershed- or site-specific water quality requirements. It will be presumed that a stormwater management system complies with this performance standard if: (1) It is sized to capture and treat the prescribed water quality treatment volume, which is defined as the runoff volume resulting from the first 1.2 inches of rainfall from a site; and (2) Appropriate structural stormwater controls are selected, designed, constructed, and maintained according to the specific criteria in the Stormwater Management Design Manual. Runoff from hotspot land uses and activities identified by Walker County must be adequately treated and addressed through the use of appropriate structural stormwater controls and pollution prevention practices. ## History (Ord. of 12-1-2004, § 4.1)