A commercial driveway shall not be located upon a shortcrest vertical curve or on a sharp horizontal curve. All commercial driveways should be designed and constructed so that motorists will have adequate sight distance in both directions along the road. A permit will not be issued for a commercial driveway when adequate sight distance is not available. Sight distance as used for commercial driveways should be measured from a point 15 feet from the edge of the edge of pavement at a height of three and one-half feet above the surface of the roadway to an object on the centerline of the road two feet above the surface of the roadway. The AASHTO, A Policy on Geometric Design of Highways and Streets shall be used to determine the minimum sight distances acceptable for permitting a commercial driveway. The Public Works Department shall issue all commercial driveway permits and shall provide the inspection and enforcement regarding the proper installation of the same by the developer.