--- title: Wilkes County Code of Ordinances, Sec. 32-23. Septic tanks collection: local-codes id: local-code:wilkes-county/code/32-23 cite_as: Wilkes County, Ga., Code of Ordinances ยง 32-23 canonical_url: https://georgiacommons.org/counties/wilkes/code/32-23 md_url: https://georgiacommons.org/counties/wilkes/code/32-23.md text_url: https://georgiacommons.org/counties/wilkes/code/32-23/text source_url: https://library.municode.com/ga/wilkes_county/codes/code_of_ordinances date: 2026-11-23 status: active jurisdiction: county:wilkes jurisdiction_name: Wilkes County county_fips: "13317" corpus_version: local-codes-wilkes-county-f27c4c1a53c1 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/wilkes/code/~part-code-of-ordinances/~chapter-32/~article-ii.md previous: https://georgiacommons.org/counties/wilkes/code/32-22.md next: https://georgiacommons.org/counties/wilkes/code/32-24.md index: https://georgiacommons.org/counties/wilkes.md branch: code edition: As published by Municode, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:wilkes-county/code/32-23@2026-11-23-e6bd08d75b --- # Wilkes County Code of Ordinances, Sec. 32-23. Septic tanks > As published by Municode, retrieved 2026-11-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part - CODE OF ORDINANCES / Chapter 32 - UTILITIES / Article II - ON-SITE SEWAGE MANAGEMENT SYSTEMS (a) Minimum design and construction. Septic tanks shall be designed and constructed to equal or exceed minimum design and construction criteria established by the department as published in the current manual for on-site sewage management systems. Any person seeking approval of septic tanks to be used in on-site sewage management systems after the effective date of these rules, shall submit detailed plans and specifications for tank manufacture and such other information as may be required by the county board of health. Manufacturers and suppliers shall be subject to periodic inspection, and approved by the county board of health. (b) Location. No septic tank shall be installed less than 50 feet from existing or proposed wells/springs, or suction water lines, and tanks shall be located downgrade from wells/or springs if physically possible; less than 25 feet from lakes, ponds, streams, watercourses, or sink holes; less than ten feet from pressure water supply lines, or less than ten feet from a property line. No septic tank shall be installed less than 15 feet from a drainage ditch or embankment. Septic tanks shall be installed so as to provide ready access for necessary maintenance. Normally, the desired distance a septic tank should be located from a building foundation is at least ten feet but if conditions permit, lesser distances may be allowed by the county board of health. The county board of health, after site inspection, may require greater separation distances than cited herein due to unusual conditions of topography, or other site configuration; subsurface soil characteristics and/or groundwater interference. (c) Capacity. The liquid capacity of septic tanks for single-family dwellings shall be not less than 750 gallons for one or two bedrooms; 900 gallons for three bedrooms; 1,000 gallons for four bedrooms and 250 additional gallons for each bedroom over four. The liquid capacity of septic tanks in on-site sewage management systems for nonresidential usage shall be based on the anticipated daily sewage flow from the facility served, but in no case shall be less than 750 gallons. Septic tank capacity shall be increased by 50 percent where garbage grinders are to be used. (d) Compartmented tanks. Compartmented tanks are permissible upon approval by the county board of health. (e) Tanks in series. The county board of health may approve the installation of two septic tanks placed in series provided that the capacity of the first tank is at least 750 gallons and at least equal to the capacity of the second tank. When tanks in series are used, they shall be connected with a sealed sewer line, and all sewage shall initially enter the first tank. (f) Foundation and backfill. Septic tanks shall be constructed or installed level, on a foundation that will prevent settling; backfill shall be placed so that a stable fill results and undue strain on the tank is avoided. Earth backfill shall be free of voids, large stones, stumps, broken masonry, or other such materials. A minimum earth cover of six inches over the tank is recommended. All openings and manholes shall be constructed so as to prevent the entrance of surface water. ## History (Res. No. 05081997, att. C(290-5-26-.05), 5-8-1997)