Sec. 32-30. Grease traps.

About this text

  • As published by Municode, retrieved 2026-11-23
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Required. Grease traps shall be required for commercial or industrial establishments with on-site sewage management systems where it is determined by the county board of health that grease may be introduced into the system in quantities that may adversely affect the operation of the system.

(b) Specifications and design. Plans and specifications for grease traps shall be submitted to the county board of health for approval. Grease traps shall be designed to provide a liquid capacity of not less than 125 gallons. Effluent from grease traps shall be disposed of in a septic tank and not directly discharged to the absorption field.

(c) Construction. Grease traps shall be located, installed and constructed so that the temperature of the sewage will be reduced to permit congealing or separation of grease, and easy access for cleaning is provided.

History

The history line the source prints at the end of the section.

(Res. No. 05081997, att. C(290-5-26-.12), 5-8-1997)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:wilkes-county/code/32-30@2026-11-23-397d772799

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.