Wilkes County · Code of Ordinances
Part - CODE OF ORDINANCES / Chapter 8 - BUILDINGS AND BUILDING REGULATIONS / Article IV - FLOW RATE RESTRICTIONS ON PLUMBING FIXTURES
Sec. 8-87. Permitted construction.
About this text
- As published by Municode, retrieved 2026-11-23
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) No construction may be initiated within the unincorporated areas of the county for any residential building of any type which:
(1) Employs a gravity tank-type, flushometer valve, or flushometer-tank toilet that uses more than an average of 1.28 gallons of water per flush;
(2) Employs a showerhead that allows a flow of more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;
(3) Employs a urinal that uses more than an average of 0.5 gallons of water per flush;
(4) Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than 1.5 gallons of water per minute; or
(5) Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than 2.0 gallons of water per minute.
(b) There shall be no construction of any commercial building initiated within the unincorporated areas of the county for any commercial building of any type which does not meet the requirements of subsections (a)(1) through (5) of this section.
History
(Ord. No. 031491-D, §§ 2, 3, 3-14-1991)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.