CITY OF SOCIAL CIRCLE SEPTEMBER 2, 2025 6:00 PM City Community Room 138 East Hightower Trail Planning Commission Called Meeting Minutes Persons with hearing or speech disabilities who need to contact the City of Social Circle may place their call through The Georgia Relay Center at (800) 255-0056 (Text Telephone) or (800) 255-0135 (Voice Telephone). I. CALL TO ORDER Attendee Name Organization Title Status Arrived Departed Scott Gaither City of Social Circle Chairman Present 6:00 PM 6:29 PM Adolphus Gaither City of Social Circle Member Present 6:00 PM 6:29 PM Signora Jackson City of Social Circle Member Present 6:00 PM 6:29 PM Travis Parr City of Social Circle Member Absent Glenda Brown City of Social Circle Member Present 6:00 PM 6:29 PM Curtis Mullins City of Social Circle Member Absent John Gardner City of Social Circle Member Present 6:00 PM 6:29 PM Cody Ellis City of Social Circle City Planner Present 6:00 PM 6:29 PM II. UNFINISHED BUSINESS 1. SU--2025-005 - 0 Fairplay Rd, Also Known as Tax Parcels SC210001, SC210002, & SC2100010DP; Request for Special Use to Allow a Data Center Under Light Industrial (LI) Zoning, Chairman Scott Gaither entertained a motion to un-table item #1. Member Glenda Brown made a motion, seconded by Member Signora Jackson. All were in favor. City Planner, Cody Ellis, presented the staff report. The applicant had provided an updated site plan which was included in the agenda packets, as was other supporting documentation that the commission had requested. Staff recommended approval. The applicant did not have anything to add initially. Chairman Scott Gaither asked if based on the impervious surface limitations if they would be able to complete this project, applicant said they should be able to. Chairman Gaither also inquired about the water usage, the applicant stated that Walton County and City of Monroe had been discussing providing the raw water. He also stated that grey water is what would mostly be used. He also clarified that the generators would be located on the north side of the property. Member John Gardner asked if there was any plan to use water from the retention ponds for the cooling system, applicant stated not at this time. Chairman Scott Gaither provided a list of proposed conditions. The Commission agreed with those listed conditions. Member Adolphus Gaither made a motion to recommend approval of SU-2025-005 with the following conditions. 1.) Maximum parking spaces allowed per building is 35 spaces; 2.) Wall packs and exterior lighting mounted on the buildings shall only be placed above service entrances, shall be full cut-off fixtures, down lighting so as to not cast light or glare towards property lines or streets, and shall not be used for general site lighting purposes; 3.) Parking lot lights shall not be taller than 20-feet, shall be full cut-off fixtures and not cast light nor glare towards property lines or streets; 4.) Site lighting and photometric plan shall be completed and provided no more than 7 footcandles at the base of the light; Minutes Draft Planning Commission September 2, 2025 Persons with hearing or speech disabilities who need to contact the City of Social Circle may place their call through The Georgia Relay Center at (800) 255-0056 (Text Telephone) or (800) 255-0135 (Voice Telephone). 5.) Power substation and generator shall be screened from view on all sides that face a property line or adjacent street. Screening shall be with a dense evergreen hedge that provides an opaque visual buffer, and said hedge shall be no less than 12-feet in height at the time of planting; 6.) All utility extensions and public infrastructure improvement costs shall be the responsibility of the developer; 7.) Cooling systems shall be a closed-loop system so as to conserve water, and evaporative cooling systems shall be prohibited; and 8.) Roof-top mechanical units shall be screened on all sides by either the building parapet wall or screen wall. Member Glenda Brown seconded the motion. All were in favor. RESULT: SCHEDULED FOR Next: 9/16/2025 6:30 PM 2. SU-2025-006 - 1279 Cannon Dr & 0 Mill Rd, Also Known as Tax Parcels 0132 001E, S133 001, & S133 005A; Request for Special Use to Allow a Data Center Under Light Industrial (LI) Zoning. Chairman Scott Gaither entertained a motion to un-table item #2. Member John Gardner made a motion, seconded by Member Adolphus Gaither. All were in favor. City Planner, Cody Ellis, presented the staff report. Staff recommended approval. The applicant stated that they had some more conversations with Newton County in regard to the water. He also stated that they would pay for roadway construction through the properties. Applicant also stated that an open-cooling system would peak at 3-million per day; however, technology is anticipated to reduce this in the future. Chairman Scott Gaither listed potential conditions. Member John Gardner added a condition that the egress off of Cannon Drive be only for emergency access, no construction access. Member Glenda Brown made a motion to recommend approval with the following conditions: 1.) Maximum parking spaces allowed per building is 35 spaces; 2.) Wall packs and exterior lighting mounted on the buildings shall only be placed above service entrances, shall be full cut-off fixtures, down lighting so as to not cast light or glare towards property lines or streets, and shall not be used for general site lighting purposes; 3.) Parking lot lights shall not be taller than 20-feet, shall be full cut-off fixtures and not cast light nor glare towards property lines or streets; 4.) Site lighting and photometric plan shall be completed and provided no more than 7 footcandles at the base of the light; 5.) Power substation and generator shall be screened from view on all sides that face a property line or adjacent street. Screening shall be with a dense evergreen hedge that provides an opaque visual buffer, and said hedge shall be no less than 12-feet in height at the time of planting; 6.) All utility extensions and public infrastructure improvement costs shall be the responsibility of the developer; 7.) Cooling systems shall be a closed-loop system so as to conserve water, and evaporative cooling systems shall be prohibited; 8.) Roof-top mechanical units shall be screened on all sides by either the building parapet wall or screen wall; and 9.) Access off Cannon/Hancock Drive shall be for emergency use only and use for construction access shall be prohibited. Member Adolphus Gaither seconded the motion. All were in favor. RESULT: SCHEDULED FOR Next: 9/16/2025 6:30 PM III. ADJOURN Minutes Draft Planning Commission September 2, 2025 Persons with hearing or speech disabilities who need to contact the City of Social Circle may place their call through The Georgia Relay Center at (800) 255-0056 (Text Telephone) or (800) 255-0135 (Voice Telephone). Chairman Scott Gaither entertained a motion to adjourn. Member John Gardner made a motion to adjourn the September 2, 2025, Called Planning Commission Meeting; seconded by Member Signora Jackson. All were in favor.