County: Upson County
Upson County Board of Commissioners work session, April 1, 2026
11 pages
These are the minutes as Upson County Board of Commissioners posted them, read from the file on its own website. Georgia Commons is independent and is not affiliated with Upson County Board of Commissioners.
3 of this record's 11 pages were scanned images, read here by OCR: a letter or a number on them may be misread. The file the body posted is linked below.
Records of this meeting
Each link opens the body's own website or meeting portal.
- Minutes4.1.26 Board of Commissioners Work Session (upsoncountyga.org) · shown on this page
Summary
Written by an AI model (claude-sonnet-5-5) from the minutes below. It is not the record: the minutes are.
Commissioners heard updates on airport taxiway funding, security proposals and a draft data center ordinance, taking no recorded votes on county business.
The Upson County commissioners held a work session with no recorded votes on county business. They heard an update from Oakbridge on the employee insurance renewal and a presentation from the airport director on funding for a parallel taxiway and apron rehabilitation project, with a design schedule of payments and a preliminary construction estimate of $1,069,650. The tax commissioner reviewed security service proposals, naming his top three. A commissioner asked to review grade sheets on the HVAC maintenance contract evaluation. The board postponed the body camera discussion until the chief appraiser could attend. Draft data center ordinance standards were on the agenda, along with a truck parking ordinance. On the Historic Courthouse, the board asked for information on legally leasing it. The board also went into and out of closed (executive) session on personnel and litigation, then adjourned.
Topics taken up: employee insurance renewal; airport taxiway and apron rehabilitation funding; HVAC maintenance contract; security services proposals; body cameras for appraisal staff; data center ordinance; truck parking ordinance; Historic Courthouse leasing; zoning ordinance update.
Decisions the minutes record (1)
Each decision is followed by the sentence of the minutes that records it, copied word for word.
Postponing body camera discussion for the Chief Appraiser's staff until the Chief Appraiser can attend
The minutes: “The board decided to postpone the discuss until the Chief Appraisal could attend.”
Agenda items (5)
Found in the minutes by their headings. Where an outcome is shown, it was read by rule from the item's own words: a guide to the text, not part of the record.
The minutes
As posted on upsoncountyga.org, read November 25, 2026. Nothing below is written by Georgia Commons.
UPSON COUNTY BOARD OF COMMISSIONERS
Work Session Wednesday, April 1, 2026 9:00 A.M.
Thomaston/Upson County Airport Meeting Room
AGENDA
I. CALL TO ORDER
Chairman Dan Brue
II. ATTENDANCE
Chairman Dan Brue Vice Chairman Benjamin Watson Commissioner Paul Jones Commissioner Christopher Biggs County Manager Lonnie Joyce County Clerk Jessica Jones County Attorney Heath English Commissioner James Ellington was not in attendance.
III. NEW BUSINESS
a. Update from Oakbridge on health care expenditures and expectations for renewals
Oakbridge gave an update on the Employee insurance renewal.
b. Discussion on Project funding for Airport projects Airport Director Mitch Ellerbee presented the project to the board.
THOMASTON-UPSON COUNTY AIRPORT
THOMASTON, GEORGIA
EXHIBIT B
SCHEDULE OF PAYMENTS
GDOT PROJECT NUMBER: AP026-9000-56(293) UPSON
PID - T009571
REHABILITATE PARALLEL TAXIWAY AND APRON, DESIGN
FEDERAL STATE
ITEM DESCRIPTION TOTALCOST | % | FUNDS | % FUNDS
PART 7 STATE FUNDS FY 26 01270
1 [Project Formulation $5,982.28) 0% $0.00] 75%| $4,486.71 2 |Survey Work $11,885.97) 0% $0.00} ry $6,914.48
3 =| Geotechnical Investigation $26,372.35] 0% $0.00] 75% $19,779.26 4 — |Construction Plans $62,953.74] 0% $0.00/75%| $47,215.31] 5 |Contract Documents $11,540.19) 0% $0.00)75%| $6,655.14 | 6 Engineer's Design Report $5,825.63) 0% $0.00) 75% $5,119.22 7 = |Coordination, Review and Comments $714,710.84) 0% $0.00) 75%) $11,033.13}
TOTAL PART 1STATEFUNDSFY26| — $140,271.00 $0.00) $105,203.25)
TOTALPROJECT COST| $140,271.00] $0.00] $105,203.25] Federal Award Fund Activity
FAA Federal Grant and FAIN # Date Amount Source Code
STATE FY26 WA $105,203.25 01270 AVIA
Total Maximum Obligation of State Funds this Contract: $105,203.25 Thomaston-Upson County Airport
Parallel Taxiway and Apron Pavement Rehabiliation Preliminary Cost Estimate Prima n Item Description Qty. —_- Unit Unit Cost Total 1 Mobilization (10%) 1 LS $ 90,000.00 $ 90,000.00 2 Construction Entrance/Exit 4 LS $ 5,000.00 $ 5,000.00 3 12" Trench Drain 335 LF § 350.00 $ 117,250.00
4 Precast Drop Inlet Manhole 2 EA $ 7,500.00 $ 15,000.00 5 24" RCP Pipe 75 LF $¢ 100.00 $ 7,500.00
6 2" Milling 17,600 SY $ 9.00 $ 158,400.00 7 Grading Complete (for connector taxiway relocation) 1 Ls $ 15,000.00 $ 15,000.00 8 Crushed Aggregate Base (8") 1,600 SY $ 35.00 $ 56,000.00 9 Pavement Removal 800 SY $ 1250 $ 10,000.00
10 Sawcut Pavement 850 LF $ 5.00 $ 4,250.00
11. 12.5 mm Asphalt (GDOT 402) (1.5") 1,723 TON $ 150.00 $ 258,450.00 12 19mm Asphalt (GDOT 402) (3") 230 TON $ 150.00 $ 43,500.00 13 Asphalt, Open-Graded Crack Relief Interlayer (GDOT 415) (1") 1,052 TON $ 150.00 $ 157,800.00 14 Apron Marking 1 LS $ 15,000.00 $ 15,000.00
15‘ Taxiway Lighting 1 iS ¢$ 20,000.00 $ 20,000.00 16 Aircraft Tie-Down Anchors 30 EA $ 500.00 $ 45,000.00 17 Temporary Seeding 1 AC $ 2,500.00 §$ 2,500.00
18 Permanent Seeding, including minor shoulder grading 1 ACS 4,000.00 $ 4,000.00 Sub-Total: $ 994,650.00
Construction Management: $ 75,000.00 Total: $ 1,069,650.00
c. Discussion of a change in HVAC annual maintenance contract Commissioner Jones asked to review the grade sheets on how the evaluation was done.
d. Discussion with the Tax Commissioner on security services after the proposal review
Tax Commissioner Chastain reviewed the security proposals with the board. His top three were Salient, 4 Horsemen Investigations & Security and Synergy Security Service.
e. Discussion for the Chief Appraiser on body cameras for the staff
The board decided to postpone the discuss until the Chief Appraisal could attend.
f. Discussion on the Data Center Ordinance
4)
5)
6)
#)
8)
9)
Butter Requirements: 4 minimum two-hundred (200) foot wide butter shall be required along all property lines. This buffer may be located within required setbacks. Butfer requirements may be adjusted by the Planning Commission through the approval of the use permit. Buffering required under this section shall consist of undisturbed vegetation, planted trees and shrubs, ora combination of VEPetation (planted or existing) and walls and berms that effectively screen development fram the abutting road or property. The intent of these requirements is to encourage the preservation of mature and healthy, and indigenous VWeEpPetation.
HVAC and Mechanical Screening. All air conditioning units HVAC systems, and other mechanical systems located outdoors shall be visually screened from view trom public road nghts-of-way and adjacent residential properties using buildings, walls, fencing, roof elements, berms, trees, natural elements or landscaping.
Front Building Facade. The front building facade of principal structures shall be oriented toward street Tromts or adjacent public road frontage. This requirement does not apply where the building is more than 500 feet from the public right-of-way or othernwise not visible from the closest public night of way.
Security Fencing. Security fencing and walls along the right-of-way shall not be located within the required buffer unless they comply with buffering requirements.
Any security fencing installed that intersects, crosses, or otherwise interacts witha natural watenvay shall be designed, constructed, and maintained in a manner that does not impede or obstruct the natural flow of water and in Tull compliance with all local, State, and federal requirements regarding impacting State waters.
Accessory Structures. Accessory structures shall comply with applicable buffering prowisions, Accessory structures that meet the burfer setbacks are permitted.
Guardhouses and secure entry features are permitted at entrance({s) to public right of wary.
Private Roads. Private roads within the development are permitted and shall be designed and constructed in accordance with County public road standards.
10) On Site Power Generation: On site power peneration using natural gas, solar, battery storage, or other technologies is permitted as an accessory use. Emergency diesel eenerators are permitted without separate approval prowided they comply with noise, screening, and all other pertinent requirements and are otherwise compliant with our ordinances and state law. Power Generation via a steam-based power system shall only be authorized if specifically approved by the Planning Commission as part of use permit approval.
11) Lighting. ALL outdoor lighting shall use full cutoff fixtures, limited to 3,500K, and be configured to prevent light spillage onto adjacent properties.
12) Noise: Upon submission of an application for 4 building permit for a principal data center structure, said application shall include sound level modeling that complies with the levels established herein. Sound levels at any property line shall mot exceed the dB levels set forth herein except during emergency generator testing.
which is limited to one test period perweek on weekdays between 11:00 4M and 1:00 Pri.
Data center: 55 dBA daytine (7:00 AMI— 7:00 Pi) / 45 dBA nighttime (7:00 PM — 7:00 AT)
13) Water consumption: Operations shall use closed-loop cooling systems or equivalent technologies to minimize water usage beyond initial system charging and personnel needs. Non-closed loop and evaporative cocling systems are prohibited.
4 public water supply is required. The drilling of operation of wells for water supply is prohibited.
14) Traffic management: A building permit application for a data center shall include a traffic impact study that identifies measures to minimize disruptions to local roads caused by heavy equipment and material transport.
15) Environmental Impact Study: An application for a use permit for a data center shall be accompanied by a baseline environmental impact study acceptable to the Planning and #{oning Director, the contents of which shall include information on potential impacts to air quality, water resources, energy feneration, noise, light, traffic, natural resources, and archaeological or cultural resources. The study shall alse include information on mitigation of those impacts. The information provided
shall be considered by the Commission in determining whether to approve or deny the application. Environmental benchmarks, over and above those in the baseline study, shall be identified by the Board of Commissioners upon approving any use permk. A study demonstrating compliance with such benchmarks shall be provided to the Director upon application for a building permit.
16) Decommissioning Plan: 4 building permit application for a data center shall include a decommissioning plan that includes detailed procedures for the management, recycling, and disposal of electronic waste and all other materials. The Decommissioning Plan shall also include provisions addressing the proper handling, recycling, and disposal of electronic waste and other materials generated as aresult of future technological upgrades or equipment replacements. The plan shall include a financial surety, such as 4 bond or letter of credit, in an amount sufficient to cover the estimated costs of decommissioning, as determined by the
County.
17) Waste Water: Data centers shall connect to a publicly owned municipal or county Sewer system. Where municipal or county sewer service is not available, on-site Wastewater treatment and disposal systems are prohibited. The building permit application shall include 4 wastewater management plan that addresses:
i. a. Pretreatment methods for process wastewater (including cocling tower Blowdown, water treatment reject, and any other non-sanitary flows) to meet all applicable local sewer-use ordinance limits prior to discharee into the public system;
i. & Estimated daily wastewater volumes under normal operation and during maintenance events; and
ti, c. Procedures for proper handling and disposal of any wastewater or
sludge generated during equipment decommissioning or end-of-life of the facility.
18) Other Regulatory Rules and Regulations. All other local, State, and tederal regulations shall be applicable. If there is 4 conflict between this Ordinance and such local, State and federal regulations, the more rigorous requirement shall conmtrot..
Section 5. Application and Approwal
g. Discussion on the Truck Parking Ordinance
h. Discussion on the future of the Historic Courthouse The board discussed options for leasing the Historic Courthouse. They requested information on the options to legally lease it.
i. Update on the Zoning Ordinance The County Manager is working with Woods to update the zoning ordinance. He will be forthcoming with updates as he has them.
IV. EXECUTIVE SESSION – Personnel and Litigation
A motion was made by Commissioner Watson with a second from Commissioners Jones to go into executive session.
Motion passed.
A motion was made by Commissioner Jones with a second from Commissioners Watson to exit executive session and go back in to regular session.
Motion passed.
V. ADJOURNMENT
A motion was made by Commissioner Jones with a second from Commissioners Biggs to adjourn the meeting.
Was Not In Attendance Chairman Dan R. Brue II Commissioner James Ellington
Chairman Benjamin Watson Commissioner Christopher Biggs
Commissioner Paul Jones