--- title: Norcross Zoning Board of Appeals regular meeting minutes, August 27, 2026 collection: local-meetings id: minutes:2026-08-27/norcross-zoning-board-of-appeals cite_as: Norcross Zoning Board of Appeals regular meeting minutes, August 27, 2026 canonical_url: https://georgiacommons.org/meetings/2026-08-27/norcross-zoning-board-of-appeals md_url: https://georgiacommons.org/meetings/2026-08-27/norcross-zoning-board-of-appeals.md text_url: https://georgiacommons.org/meetings/2026-08-27/norcross-zoning-board-of-appeals/text source_url: https://norcrossga.api.civicclerk.com/v1/Meetings/GetMeetingFileStream(fileId=4902,plainText=false) date: 2026-08-27 jurisdiction: city:norcross jurisdiction_name: Norcross place_fips: "1355776" license: Public record of Norcross Zoning Board of Appeals, from its own website or meeting portal publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. version: Minutes as posted version_id: minutes:2026-08-27/norcross-zoning-board-of-appeals@rcb1df7948042 retrieved: 2026-11-12T12:44:24.299755+00:00 --- # Norcross Zoning Board of Appeals regular meeting minutes, August 27, 2026 - Body: Norcross Zoning Board of Appeals - Date: August 27, 2026 - Time: 18:30 ## Records of this meeting - Minutes: https://norcrossga.api.civicclerk.com/v1/Meetings/GetMeetingFileStream(fileId=4902,plainText=false) (in Georgia Commons as `minutes:2026-08-27/norcross-zoning-board-of-appeals`) ## Georgia Commons summary (AI-written) Written by AI from the record below. It is not the record and is never a source: cite the record's own words. Zoning Board of Appeals denied a lot width variance for three homes on Sunset Drive and approved a conditioned garage variance at 53 Born Street. The Zoning Board of Appeals, with four of five members present and the vice chair presiding, acted on two variance requests. The board denied a variance from the minimum lot width requirement at 727 Sunset Drive and Parcel 6273 191, which would have allowed two lots to be re-subdivided into three for three new homes. Staff had recommended denial, and five residents spoke in opposition, citing runoff, flooding, setbacks, driveway widths and development standards. The board then approved, with conditions, a variance for a detached garage at 53 Born Street: a two-foot side setback on the northern line instead of five feet, and a top-of-roof height of 22 feet 11 inches instead of the 12-foot maximum. Both votes were 4-0. The board also approved the July 23, 2026 minutes. Topics: variance at 727 Sunset Drive; minimum lot width requirement; re-subdivision into three lots; variance at 53 Born Street; detached garage height and setback; resident opposition to subdivision. Decisions the record states (each with the record's own sentence): - Variance from minimum lot width to re-subdivide two lots into three at 727 Sunset Drive and Parcel 6273 191: Failed, 4-0. The record: "The Zoning Board of Appeals voted to deny the variance request." - Variance for height and side setback of a detached garage at 53 Born Street, with conditions: Adopted, 4-0. The record: "The Zoning Board of Appeals voted to approve the variance request with the following conditions:" ## Minutes City of Norcross 65 Lawrenceville Street Norcross, GA 30071 Meeting Minutes Thursday, August 27, 2026 6:30 PM 2nd Floor Conference Room Zoning Board of Appeals Michael Walsh, Chair Bob Evely, Vice Chair Naim Harrison Taylor Walker Eleanor Gilchrest A. Call to Order The meeting was called to order at 6:30 PM by Vice Chair Bob Evely. B. Roll Call Attendee Name Title Status Arrived Michael Walsh Chair Not Present Bob Evely Vice Chair Present Naim Harrison Board member Present Eleanor Gilchrest Board member Present Taylor Walker Board member Present C. Presentation of previous meeting minutes for acceptance and acceptance of the agenda as presented for the scheduled meeting. A motion to approve the July 23, 2026, Zoning Board of Appeals Meeting Minutes. RESULT: APPROVED [UNANIMOUS] 4-0 MOVER: Naim Harrison, Board Member SECONDER: Eleanor Gilchrest, Board Member AYES: Walker, Harrison, Gilchrest, Evely ABSENT: Michael Walsh, Board Member D. Ongoing Business — None E. New Business 1. 2026-293: ZBA2026-004 — Request for Variance (727 Sunset Drive and Parcel 6273 191) Item Summary The applicant is requesting a variance from Chapter 200 – Land Use and Zoning, Article 1 – Zoning Districts and Use Provisions, Division 2 – Single-Family Residential Districts, Section 201-6 – R100 Single-Family Residence, subsection (b) – R100 lot development standards. The applicant is requesting relief from the minimum lot width requirement in order to re-subdivide two existing lots into three lots for the placement of three new homes. Staff recommended denial of the variance request. Staff Presentation Staff presented the findings of the requested variance and provided a staff recommendation for denial. Reny Nguyen represented Ly Phillips and presented the applicant’s request for a variance to Section 201-6(b) of the Unified Development Ordinance regarding the minimum lot width requirement. The applicant is proposing to re-subdivide two existing lots into three lots for the placement of three new homes. Ben Loecken, Carlos Seoane, Marlene Janos, Avery Harrison, and Debby Seoane spoke in opposition to the request and raised concerns regarding maintaining Norcross development standards in the area, water runoff, flooding, setbacks, driveway and access widths, aesthetic separation, and landscape plantings. Board Action/Motion The Zoning Board of Appeals voted to deny the variance request. The motion passed unanimously. RESULT: DENIED [UNANIMOUS] 4-0 MOVER: Bob Evely, Vice Chair SECONDER: Taylor Walker, Board Member AYES: Walker, Harrison, Gilchrest, Evely ABSENT: Michael Walsh, Board Member 2. 2026-294: ZBA2026-006 — Request for Variance (53 Born Street) Item Summary The applicant is requesting a variance from Chapter 200 – Land Use and Zoning, Article 1 – Zoning Districts and Use Provisions, Division 2 – Single-Family Residential Districts, Section 201-7 – R75 Single-Family Residence, subsection (b) – R75 lot development standards. The applicant is requesting relief from the maximum height allowed and minimum side yard setback for an accessory structure (detached garage). Staff recommended approval with conditions. Staff Presentation Staff presented the findings of the requested variance and provided a staff recommendation for approval with the following conditions: 1. Reduce the setback for an accessory structure (proposed garage) from the code-required five (5) feet to three (3) feet along the northern property line, as shown on the submitted site plan. 2. Increase the maximum height allowed for an accessory structure (proposed garage) from the maximum allowed height of 12 feet to a proposed top-of-roof height of 22 feet 11 inches. Robert Forro represented David Morelock and presented the applicant’s request for a variance to Section 201-7(b) of the Unified Development Ordinance regarding the maximum height and minimum setback requirements for an accessory structure (detached garage). Mr. Forro clarified the setback request, stating that the proposed garage would encroach three (3) feet into the required setback, resulting in a two (2)-foot setback. Board Action/Motion The Zoning Board of Appeals voted to approve the variance request with the following conditions: 1. Reduce the setback for an accessory structure (proposed garage) from the code-required five (5) feet to two (2) feet along the northern property line, as shown on the submitted site plan. 2. Increase the maximum height allowed for an accessory structure (proposed garage) from the maximum allowed height of 12 feet to a proposed top-of-roof height of 22 feet 11 inches. RESULT: APPROVED [UNANIMOUS] 4-0 MOVER: Bob Evely, Board Member SECONDER: Eleanor Gilchrest, Board Member AYES: Walker, Harrison, Gilchrest, Evely ABSENT: Michael Walsh, Board Member F. ADDITIONAL INPUT AND/OR DISCUSSION NOT OTHERWISE ADDRESSED BY THIS AGENDA G. Adjourn The meeting adjourned at 7:19 PM by Naim Harrison, seconded by Taylor Walker. The vote was unanimous, 4-0.