Forsyth · Code of Ordinances
Chapter 10 - ENVIRONMENT / Article I - FLOOD DAMAGE PREVENTION / Division II - PROVISIONS FOR FLOOD DAMAGE REDUCTION
Sec. 10-21. Building standards for structures and buildings authorized adjacent to the future-conditions
About this text
- As posted on the city's website, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
floodplain.
(a) Residential buildings. For new construction and substantial improvement of any principal residential building or manufactured home, the elevation of the lowest floor, including basement and access to the building, shall be at least three feet above the base flood elevation or one foot above the futureconditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on
exterior walls shall be provided in accordance with standards of Section 10-19(e)(1).
(b) Non-residential buildings. For new construction and substantial improvement of any principal nonresidential building, the elevation of the lowest floor, including basement and access to the building, shall be at least one foot above the level of the base flood elevation or at least as high as the futureconditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on
exterior walls shall be provided in accordance with standards of Section 10-19(e)(1). Non-residential buildings may be floodproofed in lieu of elevation.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.