Acworth · Zoning Ordinance
Appendix B - ZONING ORDINANCE
73-13.11. Sanitary Sewers.
About this text
- As published by Municode, current through 2026-02-09
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Except as herein provided, each lot or other site in a subdivision shall be connected to a public sanitary sewage system by lines of sufficient size to accommodate the anticipated sewage load. Lot service connections shall be stubbed to the property line so that there will be no necessity for cutting into the pavement in order to make future connections. The subdivider shall pay the cost of, or guarantee payment for, the cost of said installation in a manner suitable to the City of Acworth.
B. Sewer plan, showing the seal of a registered professional engineer and showing the proposed sewer system in plan and profile as designed in accordance with the State of Georgia 1983 State Highway Department Specifications, volumes I and II, shall be submitted, reviewed, and subject to final approval prior to installation.
C. Whenever a sanitary sewage system is not available within a reasonable distance, septic tanks may be permitted upon obtaining special permission of the Cobb County Health Department. For septic tank installation, the minimum lot size shall be one acre with 100 feet frontage, or greater if so required by the health department. The following information shall be submitted to the health department for consideration of septic tank approval:
1. Topographic information for each lot on which a septic tank is to be installed. Contour interval shall not exceed two feet.
2. Location of all drainage facilities either natural or proposed.
3. Percolation data indicated on a plat as specified by the health department.
4. Proposed number of sanitary fixtures per dwelling unit.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.