Skip to content
Georgia Commons
Menu

Acworth · Zoning Ordinance

Appendix B - ZONING ORDINANCE / 73-8 - SITE DEVELOPMENT

73-8.4. Fire Safety Requirements.

About this text

  • As published by Municode, current through 2026-02-09
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

A. Accessibility for fire equipment on hard surfaced sub-base (subgrade plus an asphalt first layer or bound crushed stone) shall be maintained through all stages of construction from the time framing begins.

B. Minimum width of private access driveways within a development, excluding parking, shall be 20 feet, and the minimum turning radius shall be 35 feet.

C. Fire hydrants and water service shall be installed to within 300 feet of units under construction before proceeding with framing.

73-8.5 Dumpsters.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:acworth/zoning/73-8.4@2026-02-09-26f7d25efc

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.